Wireless Remote Kit Installation

WARNING
STATIC SHOCK HAZARD
This equipment must be grounded. Improper
grounding, setup, or usage of the system can cause
static shock. To prevent shock:
Turn off and disconnect power at main switch
before disconnecting any cables and before
installing equipment.
Connect only to grounded power source.
All electrical wiring must be done by a qualified
electrician and comply with all local codes and
regulations.
Transmitter Nodes (1) and Remote Operator
Stations (3) can be installed in the hazardous location.
The Gateway Module (4) is installed in the
non-hazardous location and is connected directly to the
ProDispense Control Panel (11) and Fluid Panel (12).
See 26C266 Kit Mounting Instructions, page 16, and
Cable Connections, page 17, for more detailed
instructions.
The wireless remote kit can be installed either with or
without barrier enclosures. The typical installation
shown in F
. 4 on page 12 represents an installation
IG
without barrier enclosures. With this installation, the
wireless remote kit can be integrated into an existing
ProDispense setup with very few changes to existing
components.
NOTE: If you are also installing barrier enclosures, the
notes in F
. 4 include considerations for integrating
IG
barrier enclosures with the wireless remote kit. See
Barrier Enclosure Installation, page 6, for more
information about installing barrier enclosures.
3A6715B

Grounding

WARNING
FIRE AND EXPLOSION, AND ELECTRIC SHOCK
HAZARD
Flammable fumes, such as solvent and paint fumes,
in work area can ignite or explode. Paint or solvent
flowing through the equipment can cause static
sparking. Improper grounding can cause electric
shock. Grounding provides an escape wire for the
electric current. The equipment must be grounded to
reduce the risk of static sparking and electric shock.
Transmitter Nodes (1) and Remote Operator
Stations (3): Mount to a grounded support structure for
dissipation of static charges. See F
Gateway Modules (4): Mount to a grounded structure
to prevent static build-up. See F
ProDispense Components (9-13): Ground as
instructed in the ProDispense operations manual
(3A3469).
26C266 Wireless Remote
. 4.
IG
. 4.
IG
11