Barrier Enclosure Control Drawing; And 25B223) - Graco 26C266 Manual

Haz loc wireless remote & meter / solenoid barriers
Table of Contents

Advertisement

Barrier Enclosure
Barrier Enclosure Control Drawing (25E765 and 25B223)
Non-Hazardous Location
1
Barrier dual channel p/n 111985
G
Stahl 9002/13-280-110-001
2
Barrier dual channel p/n 514895
1
G
Stahl 9001/01-280-110-101
2
G
See the control drawing for each IS barrier.
Install in accordance with the National Electrical Code
(NEC) and any applicable local codes.
F
. 3 Barrier Control Drawing
IG
8
3
4
Entity Parameters
Uo 28 Volts
Io
107 mA
Po 749 mW
Co 9.6 mH
Lo 0.65 µH
3
4
Entity Parameters
Uo 28 Volts
Io
100 mA
Po 700 mW
Co 11 mH
Lo 0.65 µH
Meter cable, 50 ft
p/n 19A751
G
Solenoid cable, 50 ft
p/n 19A948
G
Enclosure,
conductive
Hazardous Location
Ex 2 I G Ex ia IIB T3
Class I, Div 1, Group C,D T3
Entity Parameters
Ui 30 Volts
Ii
Pi 800 mW
Ci 0.4 µF
Li
Spring lever
wire connector
Ex 2 I G Ex ia IIB T3
Class I, Div 1, Group C,D T3
Blue
Red
White
Black
Entity Parameters
Spring lever
wire connector
Meter sensor,
Graco 24W650 /
24W651.
110 mA
0.01 µH
Solenoid,
MAC 411.
Ui 30 Volts
Ii
175 mA
Pi N/A
Ci 0 µF
Li
0 µH
3A6715B