Gateway Component Identification
E
F
H
K
L
F
. 8
IG
Key:
A
M12 Connector (to FCM3, Port 5); 10 ft.
D
Industrial Ethernet port (not used)
E
Rotary switches 1 (left) and 2 (right)
F
Button 1
G
Button 2
H
LED 1
J
LED 2
K
LCD Display
L
Power Input port (M12)
16
A
D
G
J
26C266 Kit Mounting Instructions
Inside Hazardous Location
The node (1) and remote operator (3) station are located
inside the hazardous location. See F
•
Use the holes in the housings as templates for the
mounting hole patterns.
•
Mount the remote operator station (3) in a
convenient location for operator access.
•
Mount the node (1) away from high-traffic areas and
exposure to fluid contamination.
NOTE: The location should provide the least
amount of signal shielding between the node (1)
and the gateway (4).
NOTE: Avoid mounting the node (1) on the back
sides of building columns or structural supports for
the building or equipment.
Outside Hazardous Location
The gateway (4) is located outside the hazardous
location with the ProDispense system and close to the
ProDispense fluid control panel. See F
•
Use the holes in the gateway's (4) housing as a
template for the mounting hole pattern.
. 4.
IG
. 4.
IG