Typical Barrier Enclosure Installation; Barrier Enclosure Wiring Diagram - Graco 26C266 Manual

Haz loc wireless remote & meter / solenoid barriers
Table of Contents

Advertisement

Typical Barrier Enclosure Installation

This is an example of how the barrier assembly kits could be integrated into a ProDispense setup. ProDispense
component installation is covered in manual 3A3469.
Non-Hazardous Location
11
F
. 1 Typical Installation with Hazardous Location Solenoid and Meter Barriers
IG
Barrier Enclosure Assembly Key:
8
Barrier Enclosure Assembly
ProDispense Key:
9
Solenoid Valve†‡
10 Fluid Flow Meter*†
11 ProDispense Control Panel
12 ProDispense Fluid Panel
13 Dispense Valve*

Barrier Enclosure Wiring Diagram

PRODISPENSE FLUID PANEL
26A131 / 26A132 / 26A165
METER CABLE
JUNCTION BOX
BLUE
9, SIGNAL
WHITE
8, COMMON
SHIELD
TERMINAL
BLOCK
F
. 2 Barrier Enclosure Wiring Diagram
IG
3A6715B
12
Non-Hazardous Location
3
RED
1
WHITE
BLACK
2
GND.
SCREW
1K
PANEL MOUNT CONNECTOR
BLUE
WHITE
SHIELD
GND.
SCREW
SOLENOID INPUT
CABLE
12
8
8
14
14 Ground Wire (24 ft, factory-installed)
*
Removed from Fluid Panel when installed in hazardous
locations; mounting hardware not included.
Must be used with a Barrier Enclosure Assembly and
approved Solenoid Valve when installed in a hazardous
location.
Do not use the Solenoid Valve provided with the ProDis-
pense Fluid Panel.
ENCLOSURE
RED
1
3
111985
BARRIER
WHITE
2
4
BLACK
GND.
SCREW
BLUE
1
3
514895
WHITE
BARRIER
2
4
SHIELD
GND.
SCREW
Hazardous Location
9
†‡
10*
Hazardous Location
METER CABLE
RED
3
50 FT.
WHITE
1
BLACK
2
CAGE CLAMP
CONNECTOR
BLUE
50 FT.
WHITE
SHIELD
SOLENOID OUTPUT
CABLE
Barrier Enclosure
13*
CONNECTS TO
GRACO METER
SENSOR
24W650/24W651
SOLENOID VALVE
19A982 MAC IS
411 SERIES
RED
BLACK
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

25e76525b223

Table of Contents