Connection - Conrad Electronic 75 15 32 Operating Instructions Manual

Auto tracking day & night camera
Table of Contents

Advertisement

Available languages

Available languages

If you connect signal transmitters to the TAMPER and RELAY outputs, run the cables through the cable
hole (2) (see illustration to the left, 1).

6.3 Connection

Explanation of connection terminals (4):
D) Video and audio signal (OUTPUT)
The cables are preinstalled. The wires in the cables are connected to the VIDEO terminal (red wire),
the AUDIO terminal (white wire) and the COM terminal (see F).
E) TAMPER relay contact connection
The TAMPER terminals are an NC contact (see fig. B). The relay output is triggered when the hous-
ing is opened. (Charge: 100 mA, 12 V)
F) COM terminal (F)
The COM terminal (F) is preconnected to the cable shields of the video output and the audio output.
G) RELAY contact connection
The RELAY terminals are an NC contact (see fig. B). The relay output is triggered when motion
is detected.
Note that the relay contact (RELAY terminal) is triggered depending on the setting
of function selector switch S1 (10). See chapter "8. a) Function selector switch
(10)".
24
Then close the housing.
A) Make sure the upper fixing clips snap into place.
B) Make sure the status LED (6) is visible through the opening
C) Tighten the fixing screw (8).
Fig. A
of the housing.
Fig. B
COM
RELAY
TAMPER
VIDEO AUDIO
N.C.
N.C.

Advertisement

Table of Contents
loading