Grandstream Networks HT801 Administration Manual page 23

Analog telephone adaptors
Table of Contents

Advertisement

Syslog Protocol
Syslog Server
Syslog Level
Send SIP Log
With Secret Key Information
Information Capture
Always Send HTTP Basic
Authentication Information
Automatic Reboot
Download Device Configuration
Download Device XML Configuration
Upload Firmware
Upload Configuration
Export Backup Configuration
If set to SSL/TLS, the syslog messages will be sent through secured TLS
Protocol to syslog server.
Default setting is UDP.
Note: The CA certificate is required to connect with the TLS server
A reboot is required to take effect.
URL or IP address of syslog server.
Note: A reboot is required to take effect.
Select the HT8xx to report the log level. Default is NONE. The level is one of EXTRA
DEBUG, DEBUG, INFO, WARNING or ERROR. Syslog messages are sent based on the
following events:
1. product model/version on boot up (INFO level)
2. NAT related info (INFO level)
3. sent or received SIP message (DEBUG level)
4. SIP message summary (INFO level)
5. inbound and outbound calls (INFO level)
6. registration status change (INFO level)
7. negotiated codec (INFO level)
8. Ethernet link up (INFO level)
9. SLIC chip exception (WARNING and ERROR levels)
10. memory exception (ERROR level)
extra syslog style (EXTRA DEBUG level)
Note: A reboot is required to take effect.
Configures whether the SIP log will be included in the syslog messages.
The default setting is No.
Allows users to make packet capture including the secret key to decrypt the
captured TLS packets. Default value is No.
Allows the user to start the Information capture process, which can be enabled with
a reboot option every day at a specific time or disabled, Disabled by default.
If set to Yes, the device will send configured username and password within HTTP
request without server sending authentication challenge.
Default is No. When "Yes, reboot every day at hour" or "Yes, reboot every week at
day" or "Yes, reboot every month at day" is checked, user can specify "Hour of the
day (0-23)" or "Day of the week (0-6)" or "Day of the month (0-30)". Default time is
Monday 1AM.
Press Download button to download device configuration file to local computer. The
filename is "config.txt". The file is plain text and not including password fields.
Press Download to download device configuration file to local computer. The
filename is "config.xml". The file will not include password fields.
Press Upload from local directory button to load the firmware file to the device from
your computer. The firmware filename should be "ht80xfw.bin" (ht802fw.bin for
HT802 for instance), "ht81xfw.bin" for HT812/HT814 or "ht818fw.bin" for HT818.
Press Upload from local directory button to load configuration file to the device from
your computer. The configuration file should be an XML file (for instance:
"config.xml"). Note: The field
is not mandatory in the document but if available only device with specified MAC
address will accept the configuration file.
Press Download button to export device backup configuration to computer.