12 Chapter 2 703t server description
Clearance
Weight of fully loaded system with
Environmental specifications
Environmental condition
Operating temperature
Non-operating (storage) temperature
Non-operating humidity
Altitude
Electrostatic discharge
Acoustic noise
Operating shock
Handling drop
Copyright © 2007, Nortel Networks
.
two SCSI hard drives
six populated boards
CD-ROM drive
floppy drive
tape drive
Nortel CallPilot
703t Server Hardware Installation
NN44200-304 01.01 Standard
5.0 23 February 2007
front: 250 mm (10 in.)
rear: 125 mm (5 in.)
side: 75 mm (3 in.)
Note: Additional side clearance is
required for service.
top: 75 mm (3 in.)
approximately 22 kg (46 lb)
Specification
10 C to 35 C (50 F to 95 F)
Maximum rate of change must not
exceed 10 C (50 F) per hour.
-40 C to 70 C (-40 F to 158 F)
95%, non-condensing at 30 C (86 F)
1829 m (6000 ft)
15 kV or more
50 dBA in a typical office ambient
temperature (18 C to 25 C [64.4 F to
77 F])
No errors with a half sine wave shock
of 2G (with 1 millisecond duration)
Operational after a free fall from 450
mm to 600 mm (18 in. to 24 in.)
(depending on weight)