Procedure When Engineering; Sinamics Configuring Procedure - Siemens SIMOTICS M 1PH8 Configuration Manual

Main motors
Hide thumbs Also See for SIMOTICS M 1PH8:
Table of Contents

Advertisement

Configuration
6.2 Procedure when engineering
6.2

Procedure when engineering

6.2.1

SINAMICS configuring procedure

Motion Control
1PH8 motors are optimized for motion control applications. They execute linear or rotary
movements within a defined movement cycle. All movements must be performed in a time-
optimized manner. As a result of these considerations, 1PH8 motors must meet the following
requirements:
• High dynamic response, e.g. short rise times
• Capable of overload, i.e. high acceleration margin
• Wide control range, i.e. high resolution for precise positioning.
The following table "Configuring procedure" is applicable for induction, synchronous-
reluctance and synchronous motors.
General procedure when engineering
The function description of the machine provides the basis when engineering the drive
application. The components are selected according to physical interdependencies and the
selection process is usually carried out in the following sequence of steps:
Table 6-1
Planning
Step
Description of configuration activity
1.
Clarification of type of drive
2.
Definition of supplementary conditions and integration into an automation system
3.
Definition of the load, calculation of the maximum load torque and selection of the motor
4.
Selection of the SINAMICS Motor Module
5.
Repetition of steps 3 and 4 for additional axes
6.
Calculation of the required DC link power and selection of the SINAMICS Line Module
7.
Selection of the line-side options (main switch, fuses, line filters, etc.)
8.
Specification of the required control performance and selection of the Control Unit, definition of
component cabling
9.
Definition of other system components (e.g. braking resistors)
10.
Calculation of the current demand of the 24 V DC supply for the components and specification
of the power supplies (SITOP devices, Control Supply Modules)
11.
Selection of the components for the connection system
12.
Configuration of drive line-up components
13.
Calculation of the required cable cross sections for power supply and motor connections
14.
Inclusion of mandatory installation clearances
204
 
See the next
chapter
See
catalog
1PH8 SIMOTICS M main motors
Configuration Manual, 12/2022, A5E51895839A