Selecting Synchronous-Reluctance Motors - Siemens SIMOTICS M 1PH8 Configuration Manual

Main motors
Hide thumbs Also See for SIMOTICS M 1PH8:
Table of Contents

Advertisement

Figure 6-5
Note
Like those for induction motors, the data sheets for the supply voltage "ALM 400V" include
additional ancillary rated points for the configuring of main spindle applications for machine
tools. These allow an extended speed range to be configured.
The theoretical curve of the maximum permissible overload capacity is shown as a limit in
the characteristic diagrams and corresponds to value P
Note
Voltage limitation
A SINAMICS Voltage Protection Module (VPM) is required for operation at speeds of n
above. Voltage Protection Modules are available for rated currents up to 200 A.
For further information, please refer to the SINAMICS S120 configuration manuals.
6.2.5

Selecting synchronous-reluctance motors

Characteristics for synchronous-reluctance motors
For synchronous-reluctance motors, the S1 characteristic (uninterrupted duty) has a response
similar to that for synchronous motors. The S1 characteristic represents the thermally maximum
possible continuous torque that can be produced.
As a result of the very low rotor losses, in the medium speed range, synchronous-reluctance
motors have a higher thermal utilization and when compared to induction motors, have a
better efficiency class. When configuring, one of two versions can be selected:
• Efficiency (IE3 to IE5)
• Performance (IE2 to IE4)
1PH8 SIMOTICS M main motors
Configuration Manual, 12/2022, A5E51895839A
Typical speed/power diagram for 1PH8 three-phase synchronous motors
6.2 Procedure when engineering
.
max
Configuration
and
max,Inv
211