Motor components and options
5.2 Options
Shaft height
Coil current AC 24 V
4.1
±10 %
A
Permitted single-use
2.2
operating energy W
E
kJ
Total moment of iner‐
0.0174
tia (Emergency Stop)
J
tot
kgm
2
Emergency stop speed
4800
n
r/min
Number of emergency
2000
stops z
1)
Opening time t
150
0
ms
Closing time t
300
2)
C1
ms
(40)
Max. 3 switching operations per hour
1)
Closing time at 230 V AC (the time in brackets refers to the closing time for a 24 V DC power supply, and the reduced closing
2)
time when using a DC circuit with 230 V AC power supply)
Figure 5-3
Explanation of terminology in the table
Holding torque Nm: on motors with shaft heights 100 ... 160, the holding torque can be
continuously set in the specified value range using an adjusting ring. The dynamic braking
torque is approximately 70 % of the set holding torque.
Speed n
Permitted single-use operating energy W
emergency stop,
W
= J
E
182
80
100
4.7
7
0.063
4500
2000
500
500
(60)
Terminology (time) for holding operation
r/min: Maximum permissible speed.
max
. x n
/182.4 x 10
(J in kgm
2
-3
tot
132
160
6.9
6.7
16
24
0.218
0.456
3600
3100
2000
2000
650
750
1000
1100
(100)
(150)
kJ: Permissible operating energy for an
E
, n in r/min)
2
Configuration Manual, 12/2022, A5E51895839A
180
225
-
-
98
210
13
3.9
3000
2800
2000
1200
300
300
80
100
1PH8 SIMOTICS M main motors