Siemens SIMOTICS M 1PH8 Configuration Manual page 176

Main motors
Hide thumbs Also See for SIMOTICS M 1PH8:
Table of Contents

Advertisement

Motor components and options
5.2 Options
The rated powers for motors for use in hazardous zones are reduced both in S1 and S6 duty
in relation to the non-explosion protected version (standard version). The deratings are taken
into account in the rating plate data:
Article No.
1PH8xxx-1xx1x-xxx1-Z, M03, or M39
1PH8xxx-1xx2x-xxx1-Z, M03, or M39
1PH8xxx-2xx1x-xxx1-Z, M03, or M39
1PH8xxx-2xx2x-xxx1-Z, M03, or M39
In hazardous areas of Zone 2 (option M03), for induction motor versions, reduce the
permissible maximum speeds (n
Article No.
1PH810x-1xxxx-xxx1-Z, M03
1PH813x-1xxxx-xxx1-Z, M03
1PH816x-1xxxx-xxx1-Z, M03
The motors with forced ventilation have newly developed separately driven fans for use in
hazardous areas. These are in conformance with the applicable directives and standards. Take
the modified dimensions from dimension drawings (SIEMENS Product Configurator).
The supply values for the separately driven fans are specified in the following table:
Article No.
1PH810x-1xx1x-xxx1-Z, M03 or M39
1PH813x-1xx1x-xxx1-Z, M03 or M39
1PH813x-2xx1x-xxx1-Z, M03 or M39
1PH816x-1xx1x-xxx1-Z, M03 or M39
1PH816x-2xx1x-xxx1-Z, M03 or M39
Note
All of the separately driven fans are equipped with 3-phase motors.
Operating conditions for shaft heights 100 to 160
When operating SIMOTICS M-1PH8 motors in Zone 2 or Zone 22 hazardous areas, carefully take
into consideration the following application conditions:
• Provide specific operating instructions for the motors for when they are used in hazardous
areas (see link and documentation in the Intranet/Internet).
• Motor versions for use in hazardous areas are not UL-approved. As a consequence, these
motors do not bear the cUR marking.
174
Version
Induction, forced ventilation
Induction, water cooling
Synchronous, forced ventilation
Synchronous, water cooling
):
max
Version
Induction
Induction
Induction
Max. current consumption at
3 AC 400 V / 50 Hz
(±10 %)
A
0.16
0.26
0.25
Derating
10 %
20 %
20 %
20 %
Maximum speed n
4350 r/min
3000 r/min
2250 r/min
3 AC 400 V / 60 Hz
(±10 %)
A
0.13
0.24
0.22
1PH8 SIMOTICS M main motors
Configuration Manual, 12/2022, A5E51895839A
max
3 AC 480 V / 60 Hz
(±10 %)
A
0.16
0.28
0.27

Advertisement