Safety Instructions; Device Components - Gira One 5023 00 Operating Instructions Manual

Switching actuator, 6-gang / blind actuator, 3-gang standard
Table of Contents

Advertisement

Switching actuator / blind actuator 16 A Standard
1

Safety instructions

Electrical devices may only be mounted and connected by electrically skilled
persons.
Serious injuries, fire or property damage possible. Please read and follow manual
fully.
Danger of electric shock on the SELV/PELV installation. Do not connect loads for
mains voltage and SELV/PELV together to the device.
For parallel connection of several motors to an output it is essential to observe the
corresponding instructions of the manufacturers, and to use a cut-off relay if neces-
sary. The motors may be destroyed.
Use only Venetian blind motors with mechanical or electronic limit switches. Check
the limit switches for correct mastering. Observe the specifications of the motor man-
ufacturers. Device can be damaged.
Do not connect any three-phase motors. Device can be damaged.
This manual is an integral part of the product, and must remain with the end cus-
tomer.
2

Device components

(1)
Button field for manual operation
(2)
Programming button and LED
(3)
Bus connection
(4)
Status LEDs for outputs
(5)
Load connections (relay outputs)
82402632
Image 1: Device components
15.12.2022