Converting Voltage To 240V - Grizzly G0962A40 Owner's Manual

10" 2 hp open-stand hybrid table saw 40th anniversary edition
Table of Contents

Advertisement

Converting Voltage
to 240V
Electrocution, shock, fire,
or damage may occur if
machine is ungrounded,
incorrectly connected to
power, or NOT connected to
a proper power supply. Only
an electrician or qualified
service personnel should
connect this machine to
power. Damage from an
improper connection or
power supply will NOT be
covered under warranty!
The voltage conversion MUST be performed by
an electrician or qualified service personnel.
The voltage conversion procedure consists of
rewiring the motor and installing the correct plug.
A wiring diagram is provided on Page 80 for your
reference.
IMPORTANT: If the diagram included on the
motor conflicts with the one on Page 80, the motor
may have changed since the manual was printed.
Use the diagram included on the motor instead.
Items Needed
Phillips Head Screwdriver #2 ..................... 1
Electrical Tape ............................ As Needed
Wire Nut (14 AWG x 3) ............................... 1
NEMA 6-15 Plug ......................................... 1
Wire Cutters/Stripper .................................. 1
To convert Model G0962A40 to 240V:
1.
DISCONNECT MACHINE FROM POWER!
2.
Cut off existing 5-15 plug.
Model G0962A40 (Mfd. Since 07/22)
3.
Open motor junction box, remove two wire
nuts indicated in Figure 6, and then discon-
nect wires.
To Switch
Remove Wire Nuts and Disconnect Wires
Figure 6. Inside motor junction box (motor pre-
4.
Use wire nuts to connect wires as indicated
in Figure 7. Twist wire nuts onto their respec-
tive wires and wrap them with electrical tape
so they will not come loose.
To Switch
Qty
Connect Wires and Secure with Nuts
Figure 7. Motor rewired to 240V.
5.
Close and secure motor junction box.
6.
Install a NEMA 6-15 plug on power cord,
according to plug manufacturer's instructions.
If plug manufacturer's instructions are not
available, NEMA standard 6-15 plug wiring is
provided on Page 80.
1
4
3
2
Ground
wired to 120V).
1
4
3
2
Ground
-15-

Advertisement

Table of Contents
loading

Table of Contents