Hantek HDG3000B Series User Manual

Hantek HDG3000B Series User Manual

Arbitrary waveform signal generator
Hide thumbs Also See for HDG3000B Series:
Table of Contents

Advertisement

Quick Links

HDG3000B
series
Arbitrary waveform signal generator
User Manual
2022.05

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HDG3000B Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Hantek HDG3000B Series

  • Page 1 HDG3000B series Arbitrary waveform signal generator User Manual 2022.05...
  • Page 2 Hantek certified HDG3000B series arbitrary waveform signal generators to meet China's national industry standards and has passed the CE certification. Contact us If you have any questions when using the products of Qingdao Hantek Electronics Co., LTD., you can obtain service and support through the following ways: Email: service@hantek.com, support@hantek.com...
  • Page 3: Table Of Contents

    Quick start ......................9 General checking ....................9 Appearance and dimension ................9 Preparation before use ..................10 4.3.1 Connect the power supply ....................10 4.3.2 Adjust the Handle ......................11 Copyright © Qingdao Hantek Electronics Co., LTD HDG3000B User manual...
  • Page 4 Set the Amplitude ......................19 5.2.4 Set the DC Offset Voltage ....................20 5.2.5 Set the Start Phase ......................20 5.2.6 Set the Duty Cycle ......................21 5.2.7 Set the Symmetry ......................22 HDG3000B User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 5 Set the Harmonic Phase ..................34 Modulation ......................35 AM Modulation ....................35 8.1.1 Select AM Modulation ..................... 35 8.1.2 Carrier Waveform Shape ....................35 8.1.3 Carrier Waveform Frequency ..................35 8.1.4 Modulation Source ......................35 Copyright © Qingdao Hantek Electronics Co., LTD HDG3000B User manual...
  • Page 6 8.3.4 Modulation Source ......................40 8.3.5 Modulation Frequency ....................41 8.3.6 Frequency Deviation ....................... 41 PM Modulation ....................41 8.4.1 Select PM Modulation ..................... 41 8.4.2 Carrier Waveform Shape ....................42 HDG3000B User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 7 8.6.2 Carrier Waveform Shape ....................45 8.6.3 Carrier Waveform Frequency ..................46 8.6.4 Modulation Source ......................46 8.6.5 FSK Rate ........................46 8.6.6 Hopping Frequency ......................47 PSK Modulation ....................47 Copyright © Qingdao Hantek Electronics Co., LTD HDG3000B User manual...
  • Page 8 QPSK Modulation .....................50 8.9.1 Select QPSK Modulation ....................50 8.9.2 Carrier Waveform Shape ....................50 8.9.3 Carrier Waveform Phase ....................50 8.9.4 Modulation Source ......................50 8.9.5 QPSK Rate ........................50 HDG3000B User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 9 4FSK Rate ........................53 8.11.6 Hopping Frequency ......................53 8.12 OSK Modulation ....................53 8.12.1 Select OSK Modulation....................54 8.12.2 Carrier Waveform Shape ....................54 8.12.3 Carrier Waveform Frequency ..................54 Copyright © Qingdao Hantek Electronics Co., LTD HDG3000B User manual...
  • Page 10 Select Sweep ....................58 Start Frequency and Stop Frequency ...............58 Center Frequency and Frequency Span ............58 Linear Sweep ....................59 Sweep Time .....................59 Return Time .....................60 Hold Time......................60 Mark Frequency ....................60 HDG3000B User manual Copyright © Qingdao Hantek Electronics Co., LTD VIII...
  • Page 11 11 Counter ....................... 67 12 Store ........................68 12.1 Store System ....................68 12.2 File Operation ....................68 13 Utility ........................71 13.1 Sync .........................71 13.2 Impedance Settings ..................72 13.3 System Settings ....................73 Copyright © Qingdao Hantek Electronics Co., LTD HDG3000B User manual...
  • Page 12 Install Keysight IO libraries suite ..............76 14.2 Remote Control via USB ..................80 15 Troubleshoot ....................... 83 16 Appendix ......................84 16.1 Appendix A: Accessories ..................84 16.2 Appendix B: Warranty summary ...............84 HDG3000B User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 13: Figures

    Figure 10.3 Gate Burst ..................64 Figure 11.1 Counter .................... 67 Figure 12.1 Store Interface ................. 68 Figure 12.2 New File Interface ................69 Figure 12.3 Rename Interface ................70 Figure 13.1 Impedance ..................72 Copyright © Qingdao Hantek Electronics Co., LTD HDG3000B User manual...
  • Page 15: Tables

    Tables Table 3.1 Knob ...................... 7 Table 3.2 Mode ..................... 8 Table 6.1 Build-In waveform ................30 Table 10.1 Table Burst type ................62 Copyright © Qingdao Hantek Electronics Co., LTD HDG3000B User manual...
  • Page 17: Safety Requirements

    Do not touch exposed connectors and components after power is switched on. ⚫ Do not operate if the product is suspected to be faulty. If you suspect that the product has been damaged, please ask qualified maintenance personnel to check it. Copyright © Qingdao Hantek Electronics Co., LTD HDG3000B User manual...
  • Page 18: Safety Terms And Symbols

    Indicates that you may cause damage to this product or other properties if you do Safety terms on the product: Warning: Indicates a potential hazard to you if you do not perform this operation. Safety symbols on the product: HDG3000B User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 19: Measurement Category

    ≤+104℉(≤+40°C): relative humidity≤90% 106℉~122℉ (+41° C ~50° C): relative humidity≤60% Warning: To avoid the danger of short circuit or electric shock, do not operate the instrument in a humid environment. Altitude Copyright © Qingdao Hantek Electronics Co., LTD HDG3000B User manual...
  • Page 20: Maintenance And Cleaning

    Do not make the LCD exposed to direct sunlight for a long time when placing the oscilloscope. Cleaning: Regularly check the oscilloscope and probe according to the requirements of the operating conditions, please follow the following steps to clean the outer surface of the HDG3000B User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 21: Environmental Precautions

    Copyright © Qingdao Hantek Electronics Co., LTD HDG3000B User manual...
  • Page 22: Product Features

    User-friendly interface design and keyboard layout bring users extraordinary experience; Rich configuration interfaces can easily realize computer control, providing more solutions to user measurement. HDG3000B User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 23: Document Overview

    Document overview Document overview This document is used to guide the user to quickly understand the front and back panels, user interfaces, and basic operation methods of the HDG3000B series signal generators. Tip: The latest version of this manual can be downloaded at (http://www.hantek.com).
  • Page 24: Table 3.2 Mode

    Model Number of channels Maximum frequency CH1/CH2 sampling rate HDG3102B 15MHz 300MS/s HDG3022B 25MHz 300MS/s HDG3042B 40MHz 300MS/s HDG3062B 60MHz 300MS/s HDG3082B 80MHz 300MS/s HDG3102B 100MHz 300MS/s Table 3.2 Mode HDG3000B User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 25: Quick Start

    If you find the instrument is damaged, not working properly, or unable to pass the performance test, please contact the dealer responsible for this business. Appearance and dimension Figure 4.1 Front view Copyright © Qingdao Hantek Electronics Co., LTD HDG3000B User manual...
  • Page 26: Preparation Before Use

    Switch: To turn off the instrument, press the power switch. Warning: To avoid electric shock, make sure the instrument is properly grounded. HDG3000B User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 27: Adjust The Handle

    Press [Utility] > Language to select the desired language. When "Chinese" or "English" is selected, the menu, help information, prompt message and interface are displayed in Chinese or English respectively. Copyright © Qingdao Hantek Electronics Co., LTD HDG3000B User manual...
  • Page 28: Product Introduction

    CH1 or CH2 to produce a sweep or burst signal (only when 1Output or 2Output is turned on). ⚫ [CH1/2]: Channel switching. Press this button to switch menu setting channel. After selecting CH1, users can set the waveforms, parameters, and configuration of CH1. HDG3000B User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 29 External storage device (USB disk) can be accessed for saving or loading settings files. The file system format of the external storage device is FAT32 and the memory is no more than 32G. Copyright © Qingdao Hantek Electronics Co., LTD HDG3000B User manual...
  • Page 30: Rear Panel

    This connector is usually used to synchronize multiple instruments (refer to the introduction in "Clock Source"). Counter (0~3.3V, external signal input) BNC connector with 500Ω nominal input impedance. It is used to accept an HDG3000B User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 31: Main Interface

    Displays the output configuration of the current channel, including waveform type, output impedance, operating mode and output state. Output Impedance: HighZ (High Impedance) or 50Ω. Mode: Modulation, Sweep, Burst or Continuous output. Menu Copyright © Qingdao Hantek Electronics Co., LTD HDG3000B User manual...
  • Page 32: Parameter Setting Method

    During parameter input, the direction keys are used to move the cursor to select the currently edited bit. When editing the file name, the arrow keys are used to move the cursor position. HDG3000B User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 33: Using The Built-In Help System

    If there are indexes for other topics in the content view, the user can rotate the knob to select a different index, press the button to enter the corresponding topic content. Press the [?] key again to exit. Copyright © Qingdao Hantek Electronics Co., LTD HDG3000B User manual...
  • Page 34: Basic Waveform Output

    The frequency displayed on the screen is the default value or the frequency previously set. When the instrument function is changed, if this frequency is valid under the new function, the instrument will still use this frequency; otherwise, the instrument would HDG3000B User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 35: Set The Amplitude

    For different waveforms, the relations between Vpp and Vrms are different. Take sine waveform as an example; the relation of the two units is as shown in the figure below. Copyright © Qingdao Hantek Electronics Co., LTD HDG3000B User manual...
  • Page 36: Set The Dc Offset Voltage

    The starting phase can be set from 0° to 360° . The default value is 0° . Press 0 Phase softkey to quickly set the phase to 0° . Press Sync softkey to synchronize the phase of the two channels (CH1 and CH2) with each other. HDG3000B User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 37: Set The Duty Cycle

    Figure 5.2 After 5.2.6 Set the Duty Cycle Duty cycle is defined as the percentage that the high level takes up in the whole period as shown in the figure below. Copyright © Qingdao Hantek Electronics Co., LTD HDG3000B User manual...
  • Page 38: Set The Symmetry

    To output a pulse, users need to set the "Width/Duty", "Leading" and "Trailing", in addition to the basic parameters (such as the frequency, amplitude, DC offset voltage, high level, low level and align phase) introduced above. HDG3000B User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 39 Duty. Press [Setting] > Duty softkey to modify the duty cycle parameters. Leading/Trailing Edge Time The leading (rising) edge time is defined as the time required for the pulse amplitude to Copyright © Qingdao Hantek Electronics Co., LTD HDG3000B User manual...
  • Page 40: Enable The Channel Output

    "5", and then select the desired unit "mV" in the pop-up menu. Press Width softkey to highlight it. Use the numeric keypad to input the width value "200", then select the unit "nsec" from the menu that pops up. HDG3000B User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 41: Figure 5.3 Setting Interface

    At this point, the specified waveform is output from CH1 based on the current configuration. Connect the CH1 output terminal to the oscilloscope and the waveform is as shown in the figure below. Figure 5.4 Output Waveform Copyright © Qingdao Hantek Electronics Co., LTD HDG3000B User manual...
  • Page 42: Arbitrary Waveform Output

    Press the softkey and select a type ("Math", "Project", "Distribution function" and "Trigonometric function", "Window function" and "biology"), and press the corresponding softkey type to select the desired waveform. Build-In Waveform HDG3000B User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 43 Analog quake waveform Radar Analog radar waveform Ripple Ripple wave of battery RoundHalf RoundHalf wave RoundsPM RoundsPM waveform StepResp Step-response signal SwingOsc Kinetic energy- time curve of swing oscillation TV signal Copyright © Qingdao Hantek Electronics Co., LTD HDG3000B User manual...
  • Page 44 SCR firing profile Surge Surge signal Math Airy Airy function Besselj BesselI function Bessely BesselII function Cauchy Cauchy distribution function Cubic Cubic function Dirichlet Dirichlet function Error function Erfc Complementary error function HDG3000B User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 45 Protuberant secant SecH Hyperbolic secant Sinc Sinc function SinH Hyperbolic sine SinInt Integral sine Sqrt Square root Tangent TanH Hyperbolic tangent Anti Trigonome ACos Arc cosine ACosH Arc hyperbolic cosine Copyright © Qingdao Hantek Electronics Co., LTD HDG3000B User manual...
  • Page 46: Table 6.1 Build-In Waveform

    Select the user-defined arbitrary waveform stored in external storage (USB drive). Loading arbitrary waveform Edit the ARB waveform by PC software and export the waveform data to the external storage device as .hwf file. HDG3000B User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 47 Arbitrary Waveform Output Press [Wave] > softkey to enter the arbitrary menu, and press Type > User softkey to select the arbitrary waveform file to load. Copyright © Qingdao Hantek Electronics Co., LTD HDG3000B User manual...
  • Page 48: Harmonic Output

    "Order” on the screen is highlighted, menu, and press Order use the numeric keypad or the direction keys and the knob to input the corresponding HDG3000B User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 49: Set The Harmonic Type

    ⚫ For the input method of amplitude value, please refer to the introduction in "Parameter Setting Method". ⚫ The amplitude units available are Vpp and mVpp. Copyright © Qingdao Hantek Electronics Co., LTD HDG3000B User manual...
  • Page 50: Set The Harmonic Phase

    "° " from the pop-up menu, or use the direction keys and knob to modify the current value. For the input Parameter Setting Method method of phase value, refer to the introduction in " ". HDG3000B User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 51: Modulation

    8.1.4 Modulation Source Press [Mod] > SignalSrc softkey to select internal, external or another ch as the Copyright © Qingdao Hantek Electronics Co., LTD HDG3000B User manual...
  • Page 52: Modulation Frequency

    The modulating waveform frequency range is 2mHz to 1MHz, and the default value is 100Hz. Note: This menu will be grayed out and disabled when other modulation sources except the internal modulation source are selected. HDG3000B User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 53: Modulation Depth

    Noise and DC could not be used as carrier waveform. 8.2.3 Carrier Waveform Frequency For different carrier waveforms, the settable range of carrier frequency is different. please refer to "Frequency Characteristics" in Specifications. The default value is 1kHz. Copyright © Qingdao Hantek Electronics Co., LTD HDG3000B User manual...
  • Page 54: Modulation Source

    ⚫ Use the numeric keypad or direction keys and knob to enter the desired frequency values. ⚫ The modulating waveform frequency range is 2mHz to 1MHz, and the default value HDG3000B User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 55: Modulation Depth

    Carrier Waveform Shape FM carrier shape: Sine (default), Square, Ramp, Pulse, Arbitrary (except DC) or Harmonic waveform. ⚫ Press [Wave] button on the front panel to select the desired carrier waveform. Copyright © Qingdao Hantek Electronics Co., LTD HDG3000B User manual...
  • Page 56: Carrier Waveform Frequency

    CH2 can be used as the modulation source. And vice versa. When selecting another channel as the modulation source, please turn on the output of that channel. HDG3000B User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 57: Modulation Frequency

    PM, the carrier phase is varied by the voltage level of the modulating waveform. 8.4.1 Select PM Modulation Press [Mod] > Type > softkey to enable PM function. ⚫ When is enabled, Sweep Burst will be disabled automatically. Copyright © Qingdao Hantek Electronics Co., LTD HDG3000B User manual...
  • Page 58: Carrier Waveform Shape

    The instrument receives the external modulation signal from the [FSK/Trig/Sync/Extmod] connector on the rear panel. At this point, the PM modulation phase deviation is controlled by the ±4V signal level on the connector. HDG3000B User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 59: Modulation Frequency

    (called the "carrier amplitude" and the "modulation amplitude") is determined by the internal signal level of the instrument or the external signal level on the [FSK/Trig/Sync/Extmod] connector on the rear panel. Copyright © Qingdao Hantek Electronics Co., LTD HDG3000B User manual...
  • Page 60: Select Ask Modulation

    When external modulation source is selected, the generator receives the external modulating signal from the [FSK/Trig/Sync/Extmod] connector on the rear panel. Note: The [FSK/Trig/Sync/Extmod] connector is different when controlling ASK and AM/FM/PM modulations externally. HDG3000B User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 61: Ask Rate

    To avoid multiple waveform changes, enable modulation after configuring the other modulation parameters. 8.6.2 Carrier Waveform Shape FSK carrier shape: Sine (default), Square, Ramp, Pulse, Arbitrary (except DC) or Harmonic waveform. Copyright © Qingdao Hantek Electronics Co., LTD HDG3000B User manual...
  • Page 62: Carrier Waveform Frequency

    ⚫ The rate range is from 2mHz to 1MHz and the default is 100Hz. Note: This menu will be grayed out and disabled when the external modulation source is selected. HDG3000B User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 63: Hopping Frequency

    The available phase ranges from 0º to 360º and the default value is 0º . Copyright © Qingdao Hantek Electronics Co., LTD HDG3000B User manual...
  • Page 64: Modulation Source

    BPSK modulation. The rate at which the output shifts between the two phases (called the "carrier phase" and the "modulation phase") is determined by the internal signal level of the instrument. HDG3000B User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 65: Select Bpsk Modulation

    The rate range is from 2mHz to 1MHz and the default is 100Hz. 8.8.6 Modulation Phase Pressing [Mod] > Phase softkey to set the modulation phase. ⚫ Use the numeric keypad or direction keys and knob to input the desired phase values. Copyright © Qingdao Hantek Electronics Co., LTD HDG3000B User manual...
  • Page 66: Qpsk Modulation

    8.9.5 QPSK Rate When internal modulation source is selected, press [Mod] > Rate softkey to set the rate at which the output phase shifts between "carrier phase" and three "modulation HDG3000B User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 67: Modulation Phase

    "Frequency Characteristics" in Specifications. The default value is 1kHz. Press [Setting] > Frequency softkey on the front panel, and then use the numeric keypad or direction keys and knob to input the desired frequency value. Copyright © Qingdao Hantek Electronics Co., LTD HDG3000B User manual...
  • Page 68: Modulation Source

    4FSK carrier shape: Sine (default), Square, Ramp, Pulse, Arbitrary (except DC) or Harmonic waveform. ⚫ Press [Wave] button on the front panel to select the desired carrier waveform. ⚫ Noise and DC could not be used as carrier waveform. HDG3000B User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 69: Carrier Waveform Frequency

    [FSK/Trig/Sync/Extmod] connector on the rear panel. When the internal crystal oscillator starts to oscillate, the instrument starts to output the carrier waveform and when the internal crystal stops oscillating, the output stops. Copyright © Qingdao Hantek Electronics Co., LTD HDG3000B User manual...
  • Page 70: Select Osk Modulation

    Source When internal modulation source is selected, the modulating waveform is set as a Square with 50% duty cycle, and the intermittence time and oscillate time of the output HDG3000B User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 71: Osk Rate

    Sweep Burst will be automatically disabled (if enabled currently). ⚫ After PWM is enabled, the instrument will generate PWM waveform with the currently specified carrier and modulating waveforms. Copyright © Qingdao Hantek Electronics Co., LTD HDG3000B User manual...
  • Page 72: Carrier Waveform Shape

    CH2 can be used as the modulation source. And vice versa. When selecting another channel as the modulation source, please turn on the output of that channel. HDG3000B User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 73: Modulation Frequency

    Duty deviation is limited by the minimum Duty and current edge time setting. When external modulation source is select, the Duty deviation is controlled by the ±4V signal level on the [FSK/Trig/Sync/Extmod] connector on the rear panel Copyright © Qingdao Hantek Electronics Co., LTD HDG3000B User manual...
  • Page 74: Sweep

    Center Frequency and Frequency Span Users can also set the sweep frequency boundaries of the sweep using a center frequency and frequency span. ⚫ Center Frequency = (|Start Frequency + Stop Frequency|) / 2 HDG3000B User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 75: Linear Sweep

    When [Sweep] is enabled, press Swep Time softkey and use the numeric keyboard or knob to change the sweep time. The default value is 1s and the settable range is from 1ms to 50Ks. Copyright © Qingdao Hantek Electronics Co., LTD HDG3000B User manual...
  • Page 76: Return Time

    Polarity to select "Positive" or "Negative". The default is "Positive". ⚫ manual: A sweep will be generated from the corresponding channel once you press [Trigger] at the front panel. HDG3000B User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 77: Trigger Output Edge

    [FSK/Trig/Sync/Extmod] connector will change from low level to high level. External Trigger: The [FSK/Trig/Sync/Extmod] connector is used as the input terminal of external trigger signal and has no trigger output Copyright © Qingdao Hantek Electronics Co., LTD HDG3000B User manual...
  • Page 78: Burst

    N Cycle Burst In N Cycle mode, the generator will output waveform with specified number of cycles after receiving trigger signal. “N Cycle”. Press [Burst] > Type softkey to select HDG3000B User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 79: Figure 10.1 N Cycle Burst

    In Gated Mode, the generator controls the waveform output according to the external signal level from the [FSK/Trig/Sync/Extmod] connector on the rear panel. softkey to select “Gate” and then press Press [Burst] > Type Polarity to set the gated Copyright © Qingdao Hantek Electronics Co., LTD HDG3000B User manual...
  • Page 80: Burst Count

    Press [Burst] > Type softkey to select Cycle. Press Trig Src softkey and select Internal, then press Period softkey, and use the numeric keypad or direction keys and HDG3000B User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 81: Burst Phase

    (if currently turned on) Once the Trigger button at the front panel is pressed. If the corresponding channel is not turned on, the trigger will be ignored. Copyright © Qingdao Hantek Electronics Co., LTD HDG3000B User manual...
  • Page 82: Gate Polarity

    Manual trigger: The generator outputs a pulse from the [FSK/Trig/Sync/Extmod] connector at the start of the burst. ⚫ External Trigger: The [FSK/Trig/Sync/Extmod] connector is used as the input terminal of external trigger signal and has no trigger output. HDG3000B User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 83: Counter

    The default value is 1s and the settable range is 10ms to 16s. Figure 11.1 Counter Copyright © Qingdao Hantek Electronics Co., LTD HDG3000B User manual...
  • Page 84: Store

    12.2 File Operation Press [Utility] > Store softkey to enter File System, users can perform a series of operations on files or directories including New, Save, Recall, Rename, Delete, and HDG3000B User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 85: Figure 12.2 New File Interface

    New menu and return to the previous menu. Save Press Save softkey to automatically create a new state file and save it. Recall Press Recall softkey to recall the state file or arbitrary waveform file. Rename Copyright © Qingdao Hantek Electronics Co., LTD HDG3000B User manual...
  • Page 86: Figure 12.3 Rename Interface

    Use the knob to select the specified file or directory and press Delete softkey to delete the selected file or directory. Refresh Press Refresh softkey to refresh the file list. HDG3000B User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 87: Utility

    ASK, FSK, PSK, OSK modulation, when external modulation is selected, there is no sync signal output. ⚫ For Sweep, when the frequency of the sweep signal is less than the mark Copyright © Qingdao Hantek Electronics Co., LTD HDG3000B User manual...
  • Page 88: Impedance Settings

    5Vpp and the output impedance is HighZ. At this point, change the impedance to 50Ω, the amplitude will reduce to half of the previous value (2.5Vpp). Note: Only the displayed values change with the parameter and the real output HDG3000B User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 89: System Settings

    Synchronization among multi-instruments: Divide the 10MHz clock source of a generator (set the clock source to "Internal") into multiple paths; then, connect them to the 10MHz In/Out connectors of the Copyright © Qingdao Hantek Electronics Co., LTD HDG3000B User manual...
  • Page 90: Power On Settings

    Offset/Low Level - Select the offset or low level as the waveform parameter that can be set. ⚫ Pulse width/duty cycle - Select the pulse width or duty cycle as the pulse parameters that can be set. HDG3000B User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 91: Save Picture

    Recall softkey to specify the file, and then press softkey to start the firmware update. Copyright © Qingdao Hantek Electronics Co., LTD HDG3000B User manual...
  • Page 92: Remote Control

    Install Keysight IO libraries suite ⚫ Remote Control via USB 14.1 Install Keysight IO libraries suite Users can download the application software package on the official website of Hantek: http://hantek.com/products/detail/17187 Or click the following website to download latest one: http://www.keysight.com/main/software.jspx?ckey=2175637&id=2175637&nid=-111 43.0.00&lc=eng&cc=GB Double click the icon to start installing.
  • Page 93 Remote Control Read License Agreement and accept. Click ‘Next’ to continue. Select a Typical and click ‘Next’ to continue. Copyright © Qingdao Hantek Electronics Co., LTD HDG3000B User manual...
  • Page 94 Remote Control Or select a Custom and click ‘Next’ to continue. Select “Install Keysight VISA as primary VISA” and click ‘Next’ to continue. HDG3000B User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 95 Remote Control Click ‘Install’ to start copying files. The installation is completed automatically. You will see the running IO program in the lower right corner of the screen. Copyright © Qingdao Hantek Electronics Co., LTD HDG3000B User manual...
  • Page 96: Remote Control Via Usb

    View the device resource The resource found will appear under the directory, and the model number and USB interface information of the instrument will also be displayed. For example, HDG3102C(USB0::0x0483::0x5740::************::0::INSTR) HDG3000B User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 97 Remote Control Control the instrument remotely Use PC software Users can download the application software package on the official website of Hantek: http://hantek.com/products/detail/17187 Double-click the Setup.exe file and install it according to the installation wizard. After the installation is complete, the software icon will be displayed on the computer desktop.
  • Page 98 Click “Send Commands To This Instrument” to open Keysight interactive IO interface. You can send commands and read data. For more information about the commands and programming, refer to the SCPI protocol manual. HDG3000B User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 99: Troubleshoot

    HDG3000B. When you encounter these faults, please follow the corresponding steps to deal with them. If you cannot solve them, please contact the local distributor or directly contact Hantek, and please provide the system information of the machine. (Get method: [Utility] ->...
  • Page 100: Appendix

    During the warranty period, if the product is proved to be defective, Hantek will repair or replace the product free of charge. Please refer to the description on Hantek official website for detailed warranty regulations.
  • Page 101 Appendix summary or any other applicable warranty card, including, but not limited to, any implied warranties of merchantability and fitness for special purpose. In no event shall Hantek be liable for indirect, special or consequential damages. Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 102 Addr: #35 Building, No. 780 Baoyuan Road, High-tech Zone, Qingdao, Shandong, China 266114 Switchboard: 400-036-7077 Email: service@hantek.com Tel: (0086)532-55678770 & 55678772 & 55678773 Zip code: 266114 Website: www.hantek.com Qingdao Hantek Electronics Co., LTD...

This manual is also suitable for:

Hdg3102bHdg3022bHdg3042bHdg3062bHdg3082b

Table of Contents