Hantek HDG3000C Series User Manual
Hantek HDG3000C Series User Manual

Hantek HDG3000C Series User Manual

Arbitrary waveform signal generator
Hide thumbs Also See for HDG3000C Series:
Table of Contents

Advertisement

Quick Links

HDG3000C
series
Arbitrary waveform signal generator
User Manual
2022.05

Advertisement

Table of Contents
loading

Summary of Contents for Hantek HDG3000C Series

  • Page 1 HDG3000C series Arbitrary waveform signal generator User Manual 2022.05...
  • Page 2 Hantek certified HDG3000C series arbitrary waveform signal generators to meet China's national industry standards and has passed the CE certification. Contact us If you have any questions when using the products of Qingdao Hantek Electronics Co., LTD., you can obtain service and support through the following ways: Email: service@hantek.com, support@hantek.com...
  • Page 3: Table Of Contents

    Quick start ......................9 General checking ....................9 Appearance and dimension ................9 Preparation before use ..................10 4.3.1 Connect the power supply ....................10 4.3.2 Adjust the Handle ......................11 Copyright © Qingdao Hantek Electronics Co., LTD HDG3000C User manual...
  • Page 4 Set the Amplitude ......................20 5.2.4 Set the DC Offset Voltage ....................21 5.2.5 Set the Start Phase ......................21 5.2.6 Set the Duty Cycle ......................22 5.2.7 Set the Symmetry ......................23 HDG3000C User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 5 Set the Harmonic Phase ..................35 Modulation ......................36 AM Modulation ....................36 8.1.1 Select AM Modulation ..................... 36 8.1.2 Carrier Waveform Shape ....................36 8.1.3 Carrier Waveform Frequency ..................36 8.1.4 Modulation Source ......................36 Copyright © Qingdao Hantek Electronics Co., LTD HDG3000C User manual...
  • Page 6 8.3.4 Modulation Source ......................41 8.3.5 Modulation Frequency ....................41 8.3.6 Frequency Deviation ....................... 42 PM Modulation ....................42 8.4.1 Select PM Modulation ..................... 42 8.4.2 Carrier Waveform Shape ....................43 HDG3000C User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 7 8.6.2 Carrier Waveform Shape ....................46 8.6.3 Carrier Waveform Frequency ..................46 8.6.4 Modulation Source ......................47 8.6.5 FSK Rate ........................47 8.6.6 Hopping Frequency ......................47 PSK Modulation ....................48 Copyright © Qingdao Hantek Electronics Co., LTD HDG3000C User manual...
  • Page 8 QPSK Modulation .....................50 8.9.1 Select QPSK Modulation ....................51 8.9.2 Carrier Waveform Shape ....................51 8.9.3 Carrier Waveform Phase ....................51 8.9.4 Modulation Source ......................51 8.9.5 QPSK Rate ........................51 HDG3000C User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 9 4FSK Rate ........................54 8.11.6 Hopping Frequency ......................54 8.12 OSK Modulation ....................54 8.12.1 Select OSK Modulation....................55 8.12.2 Carrier Waveform Shape ....................55 8.12.3 Carrier Waveform Frequency ..................55 Copyright © Qingdao Hantek Electronics Co., LTD HDG3000C User manual...
  • Page 10 Select Sweep ....................59 Start Frequency and Stop Frequency ...............59 Center Frequency and Frequency Span ............59 Linear Sweep ....................60 Sweep Time .....................60 Return Time .....................61 Hold Time......................61 Mark Frequency ....................61 HDG3000C User manual Copyright © Qingdao Hantek Electronics Co., LTD VIII...
  • Page 11 11 Counter ....................... 68 12 Store ........................69 12.1 Store System ....................69 12.2 File Operation ....................69 13 Utility ........................72 13.1 Sync .........................72 13.2 Impedance Settings ..................73 13.3 System Settings ....................74 Copyright © Qingdao Hantek Electronics Co., LTD HDG3000C User manual...
  • Page 12 Install Keysight IO libraries suite ..............77 14.2 Remote Control via USB ..................81 15 Troubleshoot ....................... 84 16 Appendix ......................85 16.1 Appendix A: Accessories ..................85 16.2 Appendix B: Warranty summary ...............85 HDG3000C User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 13: Figures

    Figure 10.3 Gate Burst ..................65 Figure 11.1 Counter .................... 68 Figure 12.1 Store Interface ................. 69 Figure 12.2 New File Interface ................70 Figure 12.3 Rename Interface ................71 Figure 13.1 Impedance ..................73 Copyright © Qingdao Hantek Electronics Co., LTD HDG3000C User manual...
  • Page 15: Tables

    Tables Table 3.1 Knob ...................... 7 Table 3.2 Mode ..................... 8 Table 6.1 Build-In waveform ................31 Table 10.1 Table Burst type ................63 Copyright © Qingdao Hantek Electronics Co., LTD HDG3000C User manual...
  • Page 17: Safety Requirements

    Do not touch exposed connectors and components after power is switched on. ⚫ Do not operate if the product is suspected to be faulty. If you suspect that the product has been damaged, please ask qualified maintenance personnel to check it. Copyright © Qingdao Hantek Electronics Co., LTD HDG3000C User manual...
  • Page 18: Safety Terms And Symbols

    Indicates that you may cause damage to this product or other properties if you do Safety terms on the product: Warning: Indicates a potential hazard to you if you do not perform this operation. Safety symbols on the product: HDG3000C User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 19: Measurement Category

    ≤+104℉(≤+40°C): relative humidity≤90% 106℉~122℉ (+41° C ~50° C): relative humidity≤60% Warning: To avoid the danger of short circuit or electric shock, do not operate the instrument in a humid environment. Altitude Copyright © Qingdao Hantek Electronics Co., LTD HDG3000C User manual...
  • Page 20: Maintenance And Cleaning

    Do not make the LCD exposed to direct sunlight for a long time when placing the oscilloscope. Cleaning: Regularly check the oscilloscope and probe according to the requirements of the operating conditions, please follow the following steps to clean the outer surface of the HDG3000C User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 21: Environmental Precautions

    Copyright © Qingdao Hantek Electronics Co., LTD HDG3000C User manual...
  • Page 22: Product Features

    User-friendly interface design and keyboard layout bring users extraordinary experience; Rich configuration interfaces can easily realize computer control, providing more solutions to user measurement. HDG3000C User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 23: Document Overview

    Document overview Document overview This document is used to guide the user to quickly understand the front and back panels, user interfaces, and basic operation methods of the HDG3000C series signal generators. Tip: The latest version of this manual can be downloaded at (http://www.hantek.com).
  • Page 24: Table 3.2 Mode

    CH1/CH2 sampling CH3 sampling channels frequency rate rate HDG3023C 25MHz 300MS/s 150MSa/s HDG3043C 40MHz 300MS/s 150MSa/s HDG3063C 60MHz 300MS/s 150MSa/s HDG3083C 80MHz 300MS/s 150MSa/s HDG3103C 100MHz 300MS/s 150MSa/s Table 3.2 Mode HDG3000C User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 25: Quick Start

    If you find the instrument is damaged, not working properly, or unable to pass the performance test, please contact the dealer responsible for this business. Appearance and dimension Figure 4.1 Front view Copyright © Qingdao Hantek Electronics Co., LTD HDG3000C User manual...
  • Page 26: Preparation Before Use

    Switch: To turn off the instrument, press the power switch. Warning: To avoid electric shock, make sure the instrument is properly grounded. HDG3000C User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 27: Adjust The Handle

    Press [Utility] > Language to select the desired language. When "Chinese" or "English" is selected, the menu, help information, prompt message and interface are displayed in Chinese or English respectively. Copyright © Qingdao Hantek Electronics Co., LTD HDG3000C User manual...
  • Page 28: Product Introduction

    CH1 or CH2 to produce a sweep or burst signal (only when 1Output or 2Output is turned on). ⚫ [CH1/2/3 or CH1/2]: Channel switching. Press this button to switch menu setting channel. After selecting CH1, users can set the waveforms, parameters, and HDG3000C User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 29 To get the context help information about any front-panel key or menu softkey, press this key and then press the button you need to get the help information for. 12. USB HOST Interface Copyright © Qingdao Hantek Electronics Co., LTD HDG3000C User manual...
  • Page 30: Rear Panel

    BNC connector with 50Ω nominal output impedance. When CH3 output is turned on (press [CH1/2/3] to select the CH3 window display, then press CH3 softkey and switch to "ON"), the corresponding connector outputs the configured waveform. HDG3000C User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 31: Main Interface

    BNC connector with 500Ω nominal input impedance. It is used to accept an external signal to be measured by the counter. USB DEVICE Interface Safety Lock Hole AC Power Socket 4.4.3 Main interface The user interface is shown in the following figure. Copyright © Qingdao Hantek Electronics Co., LTD HDG3000C User manual...
  • Page 32: Parameter Setting Method

    [Wave] button is displayed in the figure. Parameter Setting Method Users can use the numeric keypad or knob and direction keys to set parameters. HDG3000C User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 33: Numeric Keypad

    In the parameter editable state, rotating the knob will increase (clockwise) or decrease (counterclockwise) the parameter in specified steps. ⚫ When editing the file name, the knob is used to select different characters in the soft keyboard. Copyright © Qingdao Hantek Electronics Co., LTD HDG3000C User manual...
  • Page 34: Using The Built-In Help System

    If there are indexes for other topics in the content view, the user can rotate the knob to select a different index, press the button to enter the corresponding topic content. Press the [?] key again to exit. HDG3000C User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 35: Basic Waveform Output

    "Specifications". The default frequency is 1 KHz. The frequency displayed on the screen is the default value or the frequency previously set. When the instrument function is changed, if this frequency is valid under the new Copyright © Qingdao Hantek Electronics Co., LTD HDG3000C User manual...
  • Page 36: Set The Amplitude

    For different waveforms, the relations between Vpp and Vrms are different. Take sine waveform as an example; the relation of the two units is as shown in the figure below. HDG3000C User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 37: Set The Dc Offset Voltage

    The starting phase can be set from 0° to 360° . The default value is 0° . Press 0 Phase softkey to quickly set the phase to 0° . Press Sync softkey to synchronize the phase of the two channels (CH1 and CH2) Copyright © Qingdao Hantek Electronics Co., LTD HDG3000C User manual...
  • Page 38: Set The Duty Cycle

    Figure 5.2 After 5.2.6 Set the Duty Cycle Duty cycle is defined as the percentage that the high level takes up in the whole period as shown in the figure below. HDG3000C User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 39: Set The Symmetry

    To output a pulse, users need to set the "Width/Duty", "Leading" and "Trailing", in addition to the basic parameters (such as the frequency, amplitude, DC offset voltage, high level, low level and align phase) introduced above. Copyright © Qingdao Hantek Electronics Co., LTD HDG3000C User manual...
  • Page 40 The leading (rising) edge time is defined as the time required for the pulse amplitude to rise from 10% threshold to 90% threshold; while the trailing (falling) edge time is defined HDG3000C User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 41: Enable The Channel Output

    "5", and then select the desired unit "mV" in the pop-up menu. Press Width softkey to highlight it. Use the numeric keypad to input the width value "200", then select the unit "nsec" from the menu that pops up. Copyright © Qingdao Hantek Electronics Co., LTD HDG3000C User manual...
  • Page 42: Figure 5.3 Setting Interface

    At this point, the specified waveform is output from CH1 based on the current configuration. Connect the CH1 output terminal to the oscilloscope and the waveform is as shown in the figure below. Figure 5.4 Output Waveform HDG3000C User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 43: Arbitrary Waveform Output

    Select more than 160 kinds of arbitrary waveform built in HDG3000C, as shown in the following table. Press the softkey and select a type ("Math", "Project", "Distribution function" and "Trigonometric function", "Window function" and "biology"), and press the Copyright © Qingdao Hantek Electronics Co., LTD HDG3000C User manual...
  • Page 44 Discharge curve of Ni-MH battery Pahcur Current waveform of DC brushless motor Quake Analog quake waveform Radar Analog radar waveform Ripple Ripple wave of battery RoundHalf RoundHalf wave RoundsPM RoundsPM waveform StepResp Step-response signal HDG3000C User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 45 ISO7637-2 TP5B Automotive transients due to battery disconnect SCR firing profile Surge Surge signal Math Airy Airy function Besselj BesselI function Bessely BesselII function Cauchy Cauchy distribution function Cubic Cubic function Copyright © Qingdao Hantek Electronics Co., LTD HDG3000C User manual...
  • Page 46 RecipPro Protuberant reciprocal SecCon Concave secant SecPro Protuberant secant SecH Hyperbolic secant Sinc Sinc function SinH Hyperbolic sine SinInt Integral sine Sqrt Square root Tangent TanH Hyperbolic tangent Anti Trigonome HDG3000C User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 47: Table 6.1 Build-In Waveform

    Triang Triangle window (Fejer window) TukeyWin Tukey (tapered cosine) window Table 6.1 Build-In waveform User-defined Waveforms Select the user-defined arbitrary waveform stored in external storage (USB drive). Loading arbitrary waveform Copyright © Qingdao Hantek Electronics Co., LTD HDG3000C User manual...
  • Page 48 Edit the ARB waveform by PC software and export the waveform data to the external storage device as .hwf file. Press [Wave] > softkey to enter the arbitrary menu, and press Type > User softkey to select the arbitrary waveform file to load. HDG3000C User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 49: Harmonic Output

    The highest order of harmonic output cannot be greater than this setting value. Press [Wave] > Harmonic softkey on the front panel to enter the harmonic setting softkey, at this time, the "Order” on the screen is highlighted, menu, and press Order Copyright © Qingdao Hantek Electronics Co., LTD HDG3000C User manual...
  • Page 50: Set The Harmonic Type

    ⚫ For the input method of amplitude value, please refer to the introduction in "Parameter Setting Method". ⚫ The amplitude units available are Vpp and mVpp. HDG3000C User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 51: Set The Harmonic Phase

    "° " from the pop-up menu, or use the direction keys and knob to modify the current value. For the input Parameter Setting Method method of phase value, refer to the introduction in " ". Copyright © Qingdao Hantek Electronics Co., LTD HDG3000C User manual...
  • Page 52: Modulation

    8.1.4 Modulation Source Press [Mod] > SignalSrc softkey to select internal, external or another ch as the modulation source. HDG3000C User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 53: Modulation Frequency

    The modulating waveform frequency range is 2mHz to 1MHz, and the default value is 100Hz. Note: This menu will be grayed out and disabled when other modulation sources except the internal modulation source are selected. Copyright © Qingdao Hantek Electronics Co., LTD HDG3000C User manual...
  • Page 54: Modulation Depth

    For different carrier waveforms, the settable range of carrier frequency is different. please refer to "Frequency Characteristics" in Specifications. The default value is 1kHz. Press [Setting] > Frequency softkey on the front panel, and then use the numeric HDG3000C User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 55: Modulation Source

    ⚫ Use the numeric keypad or direction keys and knob to enter the desired frequency values. ⚫ The modulating waveform frequency range is 2mHz to 1MHz, and the default value Copyright © Qingdao Hantek Electronics Co., LTD HDG3000C User manual...
  • Page 56: Modulation Depth

    FM carrier shape: Sine (default), Square, Ramp, Pulse, Arbitrary (except DC) or Harmonic waveform. ⚫ Press [Wave] button on the front panel to select the desired carrier waveform. ⚫ Noise and DC could not be used as carrier waveform. HDG3000C User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 57: Carrier Waveform Frequency

    8.3.5 Modulation Frequency When internal modulation source is selected, press [Mod] > Frequency softkey to set Copyright © Qingdao Hantek Electronics Co., LTD HDG3000C User manual...
  • Page 58: Frequency Deviation

    After PM is enabled, the instrument will generate PM waveform with the currently specified carrier and modulating waveforms. To avoid multiple waveform changes, enable modulation after configuring the other modulation parameters. HDG3000C User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 59: Carrier Waveform Shape

    PM modulation phase deviation is controlled by the ±4V signal level on the connector. another ch CH1 and CH2 can be used as modulation sources reciprocally. When CH1 is used as Copyright © Qingdao Hantek Electronics Co., LTD HDG3000C User manual...
  • Page 60: Modulation Frequency

    [FSK/Trig/Sync/Extmod] connector on the rear panel. 8.5.1 Select ASK modulation Press [Mod] > Type > softkey to enable this function. HDG3000C User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 61: Carrier Waveform Shape

    8.5.5 ASK Rate When internal modulation source is selected, press [Mod] > Rate softkey to set the rate at which the output amplitude shifts between "carrier amplitude" and "modulation amplitude". Copyright © Qingdao Hantek Electronics Co., LTD HDG3000C User manual...
  • Page 62: Modulation Amplitude

    Press [Wave] button on the front panel to select the desired carrier waveform. ⚫ Noise and DC could not be used as carrier waveform. 8.6.3 Carrier Waveform Frequency For different carrier waveforms, the settable range of carrier frequency is different. HDG3000C User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 63: Modulation Source

    The range of hopping frequency depends on the carrier waveform currently selected. Refer to "Frequency Characteristics" in Specifications. Press [Mod] > HopFreq softkey. Use the numeric keypad or direction keys and knob to input the desired frequency value. Copyright © Qingdao Hantek Electronics Co., LTD HDG3000C User manual...
  • Page 64: Psk Modulation

    Square with 50% duty cycle, and the rate at which the output phase "shifts" between "carrier phase" and "modulation phase" is determined by "PSK Rate". external source When external modulation source is selected, the generator receives the external HDG3000C User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 65: Psk Rate

    After BPSK is enabled, the instrument will generate BPSK waveform with the currently specified carrier and modulating waveforms. To avoid multiple waveform changes, enable modulation after configuring the other modulation parameters. Copyright © Qingdao Hantek Electronics Co., LTD HDG3000C User manual...
  • Page 66: Carrier Waveform Shape

    QPSK modulation. The rate at which the output shifts between the four phases (called the "carrier phase" and three "modulation phases") is determined by the internal signal level of the instrument. HDG3000C User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 67: Select Qpsk Modulation

    The rate range is from 2mHz to 1MHz and the default is 100Hz. 8.9.6 Modulation Phase Press [Mod] > Phase1 Phase2/Phase3 softkeys to set the parameter. ⚫ Use the numeric keypad or direction keys and knob to input the desired amplitude Copyright © Qingdao Hantek Electronics Co., LTD HDG3000C User manual...
  • Page 68: 3Fsk Modulation

    Modulation Source 3FSK uses internal modulation source. The modulating waveform is square. 8.10.5 3FSK Rate When internal modulation source is selected, press [Mod] > Rate softkey to set the rate HDG3000C User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 69: Hopping Frequency

    "Frequency Characteristics" in Specifications. The default value is 1kHz. Press [Setting] > Frequency softkey on the front panel, and then use the numeric keypad or direction keys and knob to input the desired frequency value. Copyright © Qingdao Hantek Electronics Co., LTD HDG3000C User manual...
  • Page 70: Modulation Source

    [FSK/Trig/Sync/Extmod] connector on the rear panel. When the internal crystal oscillator starts to oscillate, the instrument starts to output the carrier waveform and when the internal crystal stops oscillating, the output stops. HDG3000C User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 71: Select Osk Modulation

    When external modulation source is selected, the signal generator receives the external modulation signal from the [FSK/Trig/Sync/Extmod] connector on the rear panel. 8.12.5 OSK Rate When internal modulation source is selected, press [Mod] > Rate softkey to set. Copyright © Qingdao Hantek Electronics Co., LTD HDG3000C User manual...
  • Page 72: Oscillate Time

    Carrier Waveform Duty Press [Wave] > Square softkey to select square as carrier waveform. Press [Setting] > Duty softkey, then input the required value through the numeric keypad or knob. HDG3000C User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 73: Modulation Source

    The modulating waveform frequency range is 2mHz to 1MHz, and the default value is 100Hz. Note: This menu will be grayed out and disabled when other modulation sources except the internal modulation source is selected. Copyright © Qingdao Hantek Electronics Co., LTD HDG3000C User manual...
  • Page 74: Duty Deviation

    Duty deviation is limited by the minimum Duty and current edge time setting. When external modulation source is select, the Duty deviation is controlled by the ±4V signal level on the [FSK/Trig/Sync/Extmod] connector on the rear panel HDG3000C User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 75: Sweep

    After modifying the frequency, the generator will restart to output the frequency sweep signal with the specified frequency. Center Frequency and Frequency Span Users can also set the sweep frequency boundaries of the sweep using a center frequency and frequency span. Copyright © Qingdao Hantek Electronics Co., LTD HDG3000C User manual...
  • Page 76: Linear Sweep

    When [Sweep] is enabled, press Swep Time softkey and use the numeric keyboard or knob to change the sweep time. The default value is 1s and the settable range is from 1ms to 50Ks. HDG3000C User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 77: Return Time

    TTL pulse with specified polarity. To set the TTL pulse polarity, press Polarity to select "Positive" or "Negative". The default is "Positive". ⚫ manual: A sweep will be generated from the corresponding channel once you Copyright © Qingdao Hantek Electronics Co., LTD HDG3000C User manual...
  • Page 78: Trigger Output Edge

    [FSK/Trig/Sync/Extmod] connector will change from low level to high level. External Trigger: The [FSK/Trig/Sync/Extmod] connector is used as the input terminal of external trigger signal and has no trigger output HDG3000C User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 79: Burst

    N Cycle Burst In N Cycle mode, the generator will output waveform with specified number of cycles after receiving trigger signal. “N Cycle”. Press [Burst] > Type softkey to select Copyright © Qingdao Hantek Electronics Co., LTD HDG3000C User manual...
  • Page 80: Figure 10.1 N Cycle Burst

    For Infinite Cycle mode, the trigger source includes "Internal", "External" or "Manual". Besides, users can set the "Phase", "Count" and "Trigger Slope" (external trigger) and "Trigger" (manual trigger). Gated Burst HDG3000C User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 81: Burst Count

    This menu will be grayed out and disabled when the burst type is set to Infinite cycle or Gated. 10.4 Burst Period Burst period is the time from the start of one burst to the start of next burst. It is only Copyright © Qingdao Hantek Electronics Co., LTD HDG3000C User manual...
  • Page 82: Burst Phase

    To set the extrenal trigger slope, press Slope softkey to select "Rising" or "Falling" and the default is "Rising". Manual trigger When manual trigger is selected, the generator can output N cycle or infinite burst. A HDG3000C User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 83: Gate Polarity

    Manual trigger: The generator outputs a pulse from the [FSK/Trig/Sync/Extmod] connector at the start of the burst. ⚫ External Trigger: The [FSK/Trig/Sync/Extmod] connector is used as the input terminal of external trigger signal and has no trigger output. Copyright © Qingdao Hantek Electronics Co., LTD HDG3000C User manual...
  • Page 84: Counter

    The default value is 1s and the settable range is 10ms to 16s. Figure 11.1 Counter HDG3000C User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 85: Store

    If other characters are used to name the file or folder, the name might be displayed in the store and recall interface abnormally. 12.2 File Operation Press [Utility] > Store softkey to enter File System, users can perform a series of Copyright © Qingdao Hantek Electronics Co., LTD HDG3000C User manual...
  • Page 86: Figure 12.2 New File Interface

    New menu and return to the previous menu. Save Press Save softkey to automatically create a new state file and save it. Recall Press Recall softkey to recall the state file or arbitrary waveform file. Rename HDG3000C User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 87: Figure 12.3 Rename Interface

    Use the knob to select the specified file or directory and press Delete softkey to delete the selected file or directory. Refresh Press Refresh softkey to refresh the file list. Copyright © Qingdao Hantek Electronics Co., LTD HDG3000C User manual...
  • Page 88: Utility

    ⚫ For Sweep, when the frequency of the sweep signal is less than the mark frequency, the sync signal is a TTL low level. When the frequency of the sweep HDG3000C User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 89: Impedance Settings

    5Vpp and the output impedance is HighZ. At this point, change the impedance to 50Ω, the amplitude will reduce to half of the previous value (2.5Vpp). Note: Only the displayed values change with the parameter and the real output Copyright © Qingdao Hantek Electronics Co., LTD HDG3000C User manual...
  • Page 90: System Settings

    Divide the 10MHz clock source of a generator (set the clock source to "Internal") into multiple paths; then, connect them to the 10MHz In/Out connectors of the other generators (set the clock source to "External) respectively. Finally, set the HDG3000C User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 91: Power On Settings

    Offset/Low Level - Select the offset or low level as the waveform parameter that can be set. ⚫ Pulse width/duty cycle - Select the pulse width or duty cycle as the pulse parameters that can be set. Copyright © Qingdao Hantek Electronics Co., LTD HDG3000C User manual...
  • Page 92: Save Picture

    Recall softkey to specify the file, and then press softkey to start the firmware update. HDG3000C User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 93: Remote Control

    Install Keysight IO libraries suite ⚫ Remote Control via USB 14.1 Install Keysight IO libraries suite Users can download the application software package on the official website of Hantek: http://hantek.com/products/detail/17187 Or click the following website to download latest one: http://www.keysight.com/main/software.jspx?ckey=2175637&id=2175637&nid=-111 43.0.00&lc=eng&cc=GB Double click the icon to start installing.
  • Page 94 Remote Control Read License Agreement and accept. Click ‘Next’ to continue. Select a Typical and click ‘Next’ to continue. HDG3000C User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 95 Remote Control Or select a Custom and click ‘Next’ to continue. Select “Install Keysight VISA as primary VISA” and click ‘Next’ to continue. Copyright © Qingdao Hantek Electronics Co., LTD HDG3000C User manual...
  • Page 96 Remote Control Click ‘Install’ to start copying files. The installation is completed automatically. You will see the running IO program in the lower right corner of the screen. HDG3000C User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 97: Remote Control Via Usb

    View the device resource The resource found will appear under the directory, and the model number and USB interface information of the instrument will also be displayed. For example, HDG3102C(USB0::0x0483::0x5740::************::0::INSTR) Copyright © Qingdao Hantek Electronics Co., LTD HDG3000C User manual...
  • Page 98 Remote Control Control the instrument remotely Use PC software Users can download the application software package on the official website of Hantek: http://hantek.com/products/detail/17187 Double-click the Setup.exe file and install it according to the installation wizard. After the installation is complete, the software icon will be displayed on the computer desktop.
  • Page 99 Click “Send Commands To This Instrument” to open Keysight interactive IO interface. You can send commands and read data. For more information about the commands and programming, refer to the SCPI protocol manual. Copyright © Qingdao Hantek Electronics Co., LTD HDG3000C User manual...
  • Page 100: Troubleshoot

    HDG3000C. When you encounter these faults, please follow the corresponding steps to deal with them. If you cannot solve them, please contact the local distributor or directly contact Hantek, and please provide the system information of the machine. (Get method: [Utility] ->...
  • Page 101: Appendix

    During the warranty period, if the product is proved to be defective, Hantek will repair or replace the product free of charge. Please refer to the description on Hantek official website for detailed warranty regulations.
  • Page 102 Appendix warranties of merchantability and fitness for special purpose. In no event shall Hantek be liable for indirect, special or consequential damages. HDG3000C User manual Copyright © Qingdao Hantek Electronics Co., LTD...
  • Page 103 Addr: #35 Building, No. 780 Baoyuan Road, High-tech Zone, Qingdao, Shandong, China 266114 Switchboard: 400-036-7077 Email: service@hantek.com Tel: (0086)532-55678770 & 55678772 & 55678773 Zip code: 266114 Website: www.hantek.com Qingdao Hantek Electronics Co., LTD...

This manual is also suitable for:

Hdg3023cHdg3043cHdg3063cHdg3083cHdg3103c