Hantek Hantek1025G User Manual
Hantek Hantek1025G User Manual

Hantek Hantek1025G User Manual

Arbitrary function generator

Advertisement

Quick Links

User's Manual
Hantek1025G
ARBITRARY FUNCTION GENERATOR
V1.0.2
www.hantek.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Hantek1025G and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Hantek Hantek1025G

  • Page 1 User’s Manual Hantek1025G ARBITRARY FUNCTION GENERATOR V1.0.2 www.hantek.com...
  • Page 2: Table Of Contents

    Content General safety summary ......................1 Introduction ..........................2 Chapter 1 Getting started ......................3 1.1 System Requirements ....................4 1.2 Installing Hardware ...................... 5 1.3 Installing Software ......................8 Chapter 2 Operating Basics....................11 2.1 The User’s Interface ....................12 2.2 The Menu System ......................
  • Page 3: General Safety Summary

    Hantek1025G General safety summary Please understand the following safety precautions to avoid injuries and damages to the product or any equipment connected. To be away from possible dangers, please be sure to follow the regulations.  Only qualified persons are allowed to do the maintenance.
  • Page 4: Introduction

    The data format of Hantek 1025G is completely compatible with that of Tektronix; it can directly read the waveform data files produced by the Tektronix oscilloscope or Tektronix waveform editor software and redisplay the waveform.
  • Page 5: Chapter 1 Getting Started

    Hantek1025G Chapter 1 Getting started This chapter focuses on the following topics:  System Requirements  Installing hardware  Installing software USER’S MANUAL...
  • Page 6: System Requirements

    Hantek1025G 1.1 System Requirements  Minimum System Requirements Operating System Windows XP/Vista/Win7/Win8 Memory 128MB Graphic Card Microsoft DirectX supported Screen resolution: 1024x768 Color depth: 16bit  Recommended System Requirements Operating System Windows XP/Vista/Win 7 Memory 256MB Graphic Card Microsoft DirectX supported...
  • Page 7: Installing Hardware

    Hantek1025G 1.2 Installing Hardware Connect the A-Type Plug of USB cable to your PC’s USB port. Connect the B-Type Plug of USB cable to the device’s USB port. New hardware is found. New hardware search wizard starts. USER’S MANUAL...
  • Page 8 Hantek1025G Choose the correct directory of the driver through the browser or search in the CD driver. New hardware wizard installs software. USER’S MANUAL...
  • Page 9 Hantek1025G Finish new hardware search wizard. USER’S MANUAL...
  • Page 10: Installing Software

    1. While in Windows, insert the installation CD into the CD-ROM drive. 2. The installation should start up automatically. Otherwise in Windows Explorer, switch to the CD-ROM drive and run "Setup.exe". 3. The Hantek 1025G Installation is started. Click 'Next' to continue. USER’S MANUAL...
  • Page 11 Hantek1025G 4. Choose a destination directory. Click 'Next' to continue. 5. Check the setup information. Click Next to start copying of files. USER’S MANUAL...
  • Page 12 Hantek1025G 6. This Status dialog is displayed during copying of files. 7. The installation is complete. USER’S MANUAL...
  • Page 13: Chapter 2 Operating Basics

    Hantek1025G Chapter 2 Operating Basics This chapter focuses on the following topics:  The User’s Interface  The Menu System  The Waveform Control System USER’S MANUAL...
  • Page 14: The User's Interface

    Hantek1025G 2.1 The User’s Interface Hantek 1025G provides users a simple and full-featured interface so that users do not have to spend a lot of time to learn. USER’S MANUAL...
  • Page 15: The Menu System

     Print Preview: Preview the current waveform  Print Setup: Configure the print setup  Exit: Exit Hantek 1025G Edit  Points Edit: Draw the waveform after click the command of Arb.  Zoom In: Zoom in the waveform. ...
  • Page 16 Hantek1025G Wave Parameter  Square: Show square waveform.  Ramp: Show ramp waveform.  Trapezia: Show trapezia waveform.  Exponent: Show exponent waveform.  AM/FM: Show AM/FM waveform. Digital IO  Pattern Generator: Set the Digital out pin as pattern generator.
  • Page 17  Sweep: Show the sweep dialog.  Open Output Power On: Save the current waveform to Hantek1025G, and generate the waveform when the Hantek1025G powers on.  Close Output Power On: Stop generates the waveform when the Hantek1025G powers USER’S MANUAL...
  • Page 18: The Waveform Control System

    Hantek1025G 2.3 The Waveform Control System Click Menu “Display”->”Show/Hide control”, you can show or hide the waveform control panel. You can change the waveform parameter such as frequency, amplitude, Y Offset, or phase. Also, it includes the frequency/counter measurement system.
  • Page 19: Chapter 3 Understanding Functions

    Hantek1025G Chapter 3 Understanding Functions This chapter focuses on the following topics:  Waveform parameter  Waveform output control  Edition of Arbitrary Waveform  Counter/Frequency Measurement  Waveform data files  Digital Input/Output  Output Power On  Synchronized Output ...
  • Page 20: Waveform Parameter

    Hantek1025G 3.1 Waveform parameter Choose waveform Press down any button of certain waveform to switch to the output of such kind of waveform. When switch to arbitrary waveform from other kind of waveform, the edition work can be done on the original wave form.
  • Page 21: Waveform Output Control

    Hantek1025G 3.2 Waveform Output Control By the following buttons to control the output dot numbers, trigger mode, output amplitude, and limit frequency of the wave filter. Single Wave: Output waveform only once. -20dB: Attenuation the waveform Ext Trig: Use the external or internal trigger system.
  • Page 22: Edition Of Arbitrary Waveform

    Hantek1025G 3.3 Edition of Arbitrary Waveform Choose “Arb” waveform, and click the menu “Edit” -> “Edit Points” to open edit points dialog. USER’S MANUAL...
  • Page 23: Waveform Data Files

    Hantek1025G 3.4 Waveform Data Files The data format of Hantek1025G is “.CSV”. Its format is compatible with the CSV file produced by the Tektronix ARB Express software. User can edit or set up the required CSV waveform and also use Excel to open and edit the CSV wave files.
  • Page 24: Frequency/Counter Measurement

    Hantek1025G 3.5 Frequency/Counter Measurement Click the “F/C ON/OFF” to turn on or off the frequency/counter measurement. Connect to the Frequency/Counter Measurement terminal, and turn on the “F/C ON/OFF”, you can see the frequency in the edit box. Turn the left right button to “C” end, you can see the counter in the edit box.
  • Page 25: Digital Input/Output

    Select Menu “Digital IO”, you can change the current digital IO mode. At the digital IO terminal on the Hantek1025G, there are 20 digital IO pins, 2 GND, 1 TRIG, 1 CTRL, 4 Digital In Pins and 12 Digital Out Pins.
  • Page 26 Hantek1025G 2. Programmable Output: Select menu “Programmable output”, then the Programmable output mode works. Select menu “Digital IO”->”Output set”, the “output set” dialog show. USER’S MANUAL...
  • Page 27 Hantek1025G By selecting one pin, that digital output pin will output high level. Otherwise, the pin will output low level. 3. Digital Input Select menu “Digital IO”->”Digital Input”, the following dialog show. If you input a high level to a digital input pin, the pin on the dialog would show H;...
  • Page 28: Output Without Pc

    Hantek1025G 3.7 Output without PC Hantek1025G can save a waveform to its own memory and work without PC. Open: Select menu “Utility” -> “Open output power on”. Then the current waveform will be saved to hardware. And the waveform will be generated every time when you connect the Hantek 1025G to power.
  • Page 29: Synchronized Output

    Hantek1025G 3.8 Synchronized output If you generate a waveform by software, there is a synchronized signal output from “SYNC” terminal. The signal is square waveform, the frequency of which is equal to the waveform you generated. For example, if you generated a 1 KHz, sine waveform, you will also generate an 1 KHz, square waveform simultaneously.
  • Page 30: External Trigger Input

    Hantek1025G 3.9 External Trigger Input Also, you can use the external trigger input to control the Hantek1025G. For example, the instrument generated a waveform, and you got a waveform on oscilloscope. Then, click the “Ext Trig” button on the interface of the software. The waveform on the oscillograph disappeared.
  • Page 31 Click the “Ext Trig” mode to switch the external trigger mode between “Fall” and “Rise”. Select the Fall mode as example. Input a signal which has fall edges to the “TRIG” pin. When the Hantek 1025G gets to the fall edge of the external signal, it begins to generate waveform.
  • Page 32: Chapter 4 Application Examples

    Hantek1025G Chapter 4 Application Examples This chapter focuses on the following topics:  Generate the simple waveform  Generate Arbitrary Waveform USER’S MANUAL...
  • Page 33: Generate The Simple Waveform

    Hantek1025G 4.1 Generate the Simple Waveform To generate a simple waveform, please do these steps as follows: Open the software. Choose the waveform type in the right control panel. Move your mouse to the waveform screen. Press the mouse left button and move, draw your own waveform.
  • Page 34: Generate Arbitrary Waveform

    Hantek1025G 4.2 Generate Arbitrary Waveform To generate a arbitrary waveform, please do these steps as follows: Open the software. Choose the “Arb” waveform in the right control panel. Move your mouse to the waveform screen. Press the mouse left button and move, draw your own waveform.
  • Page 35: Appendix

    Hantek1025G Appendix  Hardware specification  Cleaning and Maintenance USER’S MANUAL...
  • Page 36: Hardware Specification

    Hantek1025G Hardware Specification Waveform Output Channel sine: 1Hz(DC)~75MHz Frequency Range other waveform: 1Hz(DC)~25MHz Frequency Resolution 0.1% DAC Clock 200MHz Channels 1CH waveform output The sampling rate 200Msa/s Memory Depth 4KSa Vertical Resolution 12 Bits Stability <30ppm Amplitude ± 3.5V Max.
  • Page 37: Cleaning And Maintenance

    Hantek1025G Cleaning and maintenance Cleaning n order to maintain the cleanliness of equipment, you need to check whether the channels are dusty or not. Please clean the out surface of the equipment follow these matters. Use velvet cloth contact the surface of the equipment.

Table of Contents