Draining the Tanks
Figure 7
WATER INLET
3 DRAINS
[1] If the Processor has a Silver Recovery Unit connected, disconnect the Fixer Drain Tube at the input side of the
Silver Recovery Unit. See Figure
[2] Lift the blue Weir from the fixer Tank.
[3] Drain the fixer solution. Check the local codes for the correct disposal procedures.
Important
Do not interchange the Weirs.
[4] When the fixer Tank is drained, install the blue Weir.
[5] Drain the developer Tank in the same way.
Weir
red
blue
beige
7C8770 – 19JAN99
WASH
FIXER
DEVELOPER
13
on Page 17.
Tank
developer
fixer
wash
WEIRS
WASH
FIXER
DEVELOPER
Processing Solutions
H172_0503DCA