Setting the flush

Programming the settings
Flow
flush duration
pres‐
2 seconds
sure
0.1 MPa
0.5 l
(1 bar)
0.2 MPa
0.7 l
(2 bar)
0.3 MPa
0.9 l
(3 bar)
0.4 MPa
1 l
(4 bar)
0.5 MPa
1.2 l
(5 bar)
Visign for Public equipment set
Using the guide values from the table below, you can determine the
flush volume on the basis of flow pressure and flush duration:
flush duration
flush duration
5 seconds
10 seconds
1.2 l
2.1 l
1.6 l
2 l
3.7 l
2.3 l
4.3 l
2.6 l
4.8 l
Requirements:
The programming lock of the control is not active.
n
Cover the top part of the infrared ring. (e. g. with a finger or a hand).
The LED blinks twice after 10 seconds. Programming mode is
active.
The following values can be set by removing the hand:
Remove hand after
1st blinking signal
2nd blinking signal
3rd blinking signal
4th blinking signal
5th blinking signal
The LED flashes twice as confirmation of the setting.
flush duration
15 seconds
3.1 l
3 l
4.5 l
5.4 l
6.3 l
7 l
Setting
flush duration approx. 2 sec‐
onds
flush duration approx. 5 sec‐
onds
flush duration approx. 10 sec‐
onds (factory setting)
flush duration approx. 15 sec‐
onds
flush duration approx. 20 sec‐
onds
Handling
flush duration
20 seconds
4.1 l
5.9 l
7.2 l
8.3 l
9 l