3.3.2
Setting the flush
Programming the settings
Flow
flush duration
pres‐
2 seconds
sure
0.1 MPa
0.5 l
(1 bar)
0.2 MPa
0.7 l
(2 bar)
0.3 MPa
0.9 l
(3 bar)
0.4 MPa
1 l
(4 bar)
0.5 MPa
1.2 l
(5 bar)
Visign for Public equipment set
Using the guide values from the table below, you can determine the
flush volume on the basis of flow pressure and flush duration:
flush duration
flush duration
5 seconds
10 seconds
1.2 l
2.1 l
1.6 l
2 l
3.7 l
2.3 l
4.3 l
2.6 l
4.8 l
Requirements:
The programming lock of the control is not active.
n
▶
Cover the top part of the infrared ring. (e. g. with a finger or a hand).
The LED blinks twice after 10 seconds. Programming mode is
▷
active.
▶
The following values can be set by removing the hand:
Remove hand after
1st blinking signal
2nd blinking signal
3rd blinking signal
4th blinking signal
5th blinking signal
▷
The LED flashes twice as confirmation of the setting.
flush duration
15 seconds
3.1 l
3 l
4.5 l
5.4 l
6.3 l
7 l
Setting
flush duration approx. 2 sec‐
onds
flush duration approx. 5 sec‐
onds
flush duration approx. 10 sec‐
onds (factory setting)
flush duration approx. 15 sec‐
onds
flush duration approx. 20 sec‐
onds
Handling
flush duration
20 seconds
4.1 l
5.9 l
7.2 l
8.3 l
9 l
21