Siemens SIMOTION D4 Series Manual page 18

Hide thumbs Also See for SIMOTION D4 Series:
Table of Contents

Advertisement

Description
1.2 System components
Ethernet
The control unit can communicate with the following components via the Ethernet interfaces
or be embedded in an automation environment:
Table 1- 4
Component
Programming device (PG/PC)
Master computer
SIMATIC HMI device
PROFINET IO
The D4x5-2 DP/PN can communicate with the following components via the onboard
PROFINET IO interface.
Table 1- 5
Component
Programming device (PG/PC)
SIMATIC HMI device
Other controllers (e.g.
SIMOTION or SIMATIC)
Master computer
Distributed I/O systems
SIMATIC ET 200M
SIMATIC ET 200S
SIMATIC ET 200pro
SIMATIC ET 200eco PN
Other PROFINET IO I/O devices
Drive units with PROFINET IO
interface
Gateways
18
Components on the Ethernet
Function
... configures, parameterizes, programs, and tests with the
"SIMOTION SCOUT" engineering system (ES)
... communicates with other devices via UDP, TCP/IP
... is used for operating and monitoring functions. This is not an
essential requirement for the operation of a control unit.
Components on the PROFINET IO
Function
... configures, sets parameters, programs, and tests using the
"SIMOTION SCOUT" Engineering System (ES).
... is used for operating and monitoring functions. This is not an
essential requirement for the operation of a control unit.
... e.g. higher-level controller (plant controller); modular machine
concepts with multiple controls, distributed across individual
machine modules
... communicates with other devices via UDP, TCP/IP.
Modular I/O system for control cabinet installation and high
channel densities.
Finely scalable I/O system for control cabinet configuration and
particularly time-critical applications; including motor starters,
safety technology and individual grouping of load groups
Modular I/O system with IP65/67 degree of protection for machine-
related applications with no control cabinet; with features such as
compact designs, integrated PROFIsafe safety technology,
PROFINET IO connection and live module replacement.
Compact block I/O with IP65/66/67 degree of protection for
cabinet-free usage in machines with M12 connection method. Very
rugged and resistant encapsulated metal enclosure.
... convert speed setpoints into signals for controlling the motor
and supply the power required to operate the motors.
IE/AS-Interface link PN IO for the PROFINET IO gateway to
AS-Interface
PN/PN coupler for connecting two PROFINET IO networks
SIMOTION D4x5-2