Coolant connection data
The coolant connectors are for 16/13 mm PA (polyamide) pipe. For more information
on the pipes, see
Piping (page
Power systems
TN (grounded) and IT (ungrounded) systems)
Protection classes for module
Degrees of protection
(IEC/EN 60529)
Enclosure types (UL
50/50E)
Overvoltage category
(IEC/EN 60664-1)
Protective class
(IEC/EN 61800-5-1)
Optical components
The specifications of the optic cable are as follows:
•
Storage temperature: -55 ... +85 °C (-67 ... +185 °F)
•
Installation temperature: -20 ... +70 °C (-4 ... +158 °F)
•
Maximum short-term tensile force: 50 N (11.2 lbf)
•
Minimum short-term bend radius: 25 mm (1.0 in)
•
Minimum long-term bend radius: 35 mm (1.4 in)
•
Maximum long-term tensile load: 1 N (3.6 ozf)
•
Flexing: Max. 1000 cycles
ABB drive products in general utilize 5 and 10 MBd (megabaud) optical components
from Avago Technologies' Versatile Link range. Note that the optical component type
is not directly related to the actual communication speed.
Note: The optical components (transmitter and receiver) on a fiber optic link must be
of the same type.
Plastic optical fiber (POF) cables can be used with both 5 MBd and 10 MBd optical
components. 10 MBd components also enable the use of Hard Clad Silica (HCS®) cables,
which allow longer connection distances thanks to their lower attenuation. HCS®
cables cannot be used with 5 MBd optical components.
The maximum lengths of fiber optic links for POF and HCS® cables are 20 and 200
meters (65.6 ft and 656 ft) respectively.
Ambient conditions
The unit is to be used in a heated indoor controlled environment.
106).
IP00
UL Open Type
III
I
Operation installed for
stationary use
Storage in protective
package
Technical data 127
Transportation in pro-
tective package