ENTRY AREA HEAT

ENTRY AREA HEAT - DESCRIPTION/OPERATION
1.
D
/L
ESCRIPTION
OCATION
An air heater has been installed to provide additional heat to the entry area through outlets in the galley
kick panel and the jumpseat well risers.
ENTRY HTR CONT switch
Heater B1HR
Relay K1HR
ENTRY HEATER circuit breaker
2.
O
PERATION
NOTE: The entry area heater does not have a blower. The cabin Environmental Control System (ECS)
must be ON and operating to provide air flow through the heater (21-22-00).
Toggle the ENTRY HTR CONT switch to send a signal via the cabin data bus. This signal energizes
relay K1HR and sends power from the 115VAC 400Hz - CABIN BUS 2 bus to the heater. Circuit breaker
CBPG-38 provides circuit protection for the heater. An over-temperature sensor in the heater will turn the
system OFF in case of overheating.
TE-55965000-SMM
EFFECTIVITY:
Revision A
CL-604 SUPPLEMENTAL MAINTENANCE MANUAL
Table 1
lists the components and their locations.
Component (Qty)
ENTRY AREA HEAT COMPONENTS AND LOCATIONS
TABLE 1
Location
Galley Circuit Breaker Panel
Main avionics compartment
Adjacent to heater B1HR
CBPG-38
21-40-03
Page 1