12.5.4 Event status register (ESR) and event status enable register (ESE)

The ESR is defined in IEEE 488.2. It can be compared with the EVENt part of a SCPI
register. The event status register can be read out using command *ESR?.
The ESE corresponds to the ENABle part of a SCPI register. If a bit is set in the ESE
and the associated bit in the ESR changes from 0 to 1, the ESB bit in the STB is set.
The ESE register can be set using the command
*ESE?.
Table 12-3: Meaning of the bits used in the event status register
Bit No.
0
1
2
3
4
5
6
7

12.5.5 Questionable status register (STATus:QUEStionable)

This register contains information on questionable instrument states. Such states may
occur when the instrument is not operated in compliance with its specifications.
To read the register, use the query commands
STAT:QUEST[:EVEN]?.
User Manual 1173.9105.02 ─ 13
Meaning
Operation Complete
This bit is set on receipt of the command *OPC exactly when all previous commands have been
executed.
Not used
Query Error
This bit is set if either the controller wants to read data from the instrument without having sent a
query, or if it does not fetch requested data and sends new instructions to the instrument
instead. The cause is often a query which is faulty and hence cannot be executed.
Device-dependent Error
This bit is set if a device-dependent error occurs. An error message with a number between
-300 and -399 or a positive error number, which denotes the error in greater detail, is entered
into the error queue.
Execution Error
This bit is set if a received command is syntactically correct but cannot be performed for other
reasons. An error message with a number between -200 and -300, which denotes the error in
greater detail, is entered into the error queue.
Command Error
This bit is set if a command is received, which is undefined or syntactically incorrect. An error
message with a number between -100 and -200, which denotes the error in greater detail, is
entered into the error queue.
User Request
This bit is set when the instrument is switched over to manual control.
Power On (supply voltage on)
This bit is set on switching on the instrument.
Network operation and remote control