2

Technical data

2.1 Unit data

Overall system
Series
System
Function
Power supply
Max. current consumption
(heat pump/heat pump with auxiliary heating)
Max. power consumption
(heat pump/heat pump with auxiliary heating)
Sound power level W20/W35
Sound pressure level W20/W35
Electrical protection provided by customer
Dimensions (H/W/D)
Weight empty/filled
MWP 35 heat pump module
System
Function
Inverter technology
Compressor technology
Heat pump manager
Electrical auxiliary heater/heating capacity
Domestic hot-water heating (changeover valve)
Temperature operating limit (heat source, heating)
Inlet temperature, heating water, max.
Heating capacity max.
Heating capacity / compressor frequency / COP
with 10/W35
with W10/W45
with W10/W55
with W15/W35
with W15/W45
with W15/W55
8
Water/water heat pump incl. central
V/Ph/Hz
A
kW
dB(A)
dB(A)
A slow-acting
mm
kg
kW
°C
°C
kW
1
kW/Hz/COP
kW/Hz/COP
kW/Hz/COP
kW/Hz/COP
kW/Hz/COP
kW/Hz/COP
MWL 35
living space ventilation
Heating, domestic hot water and
ventilation
400/3~/50
3.7/9.75
0.75/3.75
42
31
3 x 16
2019/600/615
150/300
Water/water heat pump
Heating and hot water preparation
Series
Rotary piston
Internet / Series
Series/3.0
Series
10-35
60
3.15
2.49/45/5.09
2.35/45/3.96
2.26/45/3.20
2.69/45/5.67
2.40/45/4.06
2.42/45/3.27