REMKO MWL series
Energetic result in the overall system view
Every heat pump works particularly efficiently if the target temperatures/water temperatures are set as low as
possible.
The source heat pump in the first stage generates an ideal source temperature of 20 °C for the MWP 35
water/water heat pump module in the second stage.
If we now look at the entire system, each heat pump works extremely effectively and in the optimum energy
range for itself.
Due to the source temperature of 20 °C, no radiation losses occur at normal room temperatures. This pre-
vents overheating of shafts and passageways. In addition, heat losses are reduced to almost zero.
With this system a diaphragm expansion vessel [8] in the source circle (primary circle) is used and thus the
complete system the primary circuit and the secondary circuit (heating cycles downstream of MWL 35) is
protects. The diaphragm expansion vessel must then be dimensioned accordingly.
1
Fig. 8: Overall system
I:
Heating room
II:
1. Residential unit
III: Further residential units (congruent)
A: Ventilation unit module
B: Heat pump module
C: Drinking water storage module
1:
Heat generator source buffer tank
(here as an example: Air/water
REMKO LWM heat pump incl. circulating pump)
2:
Source buffer 20 °C
3:
PV current E-heater
4:
Smart Control Touch
5:
External probe
6:
Source pump (pressure controlled)
22
III
a
b
II
5
4
I
9
10
A
c
B
d
e
C
f
6
7
M
2
3
8
7:
Mixing valve
8:
Diaphragm expansion vessel
9:
Kitchen/Bathroom
10: Bedrooms and living rooms
11: Floor heating
12: Hot water
13: Cold water
a:
Source inlet
b:
Source return flow
c:
Heating cycle return flow
d:
Heating cycle inlet
e:
Hot water off
f:
Cold water on
11
12
13