Technical Data; Units Data Wkf/Wkf-Compact 85 - REMKO WKF-compact Series Assembly And Operating Instructions Manual

Inverter heat pumps
Hide thumbs Also See for WKF-compact Series:
Table of Contents

Advertisement

REMKO WKF / WKF-compact
2

Technical Data

2.1 Units data WKF/WKF-compact 85

Series
Function
System
Heat pump manager
Domestic water storage tank, enamelled
Electric booster heating / rated output
Domestic hot-water heating (changeover valve)
Connecting oil-/ gas boiler
Heating capacity min / max
Heating capacity / compressor
frequency / COP for A12/W35
Heating capacity / compressor
1)
frequency / COP
for A7/W35
Heating capacity / compressor
frequency / COP
1)
for A2/W35
Heating capacity / compressor
frequency / COP
1)
for A-7/W35
Heating capacity / compressor
1)
frequency / COP
for A-15/W35
Heating capacity / compressor
1)
frequency / COP
for A7/W45
Heating capacity / compressor
frequency / COP
1)
for A-7/W45
Heating capacity / compressor
frequency / COP
1)
for A7/W55
Heating capacity / compressor
1)
frequency / COP
for A-7/W55
Cooling capacity min. / max.
Cooling capacity / compressor
frequency / EER for A35/W7
Cooling capacity / compressor
frequency / EER for A35/W18
Cooling capacity / compressor
frequency / EER for A27/W18
Service limits, heating
Service limits, cooling
Supply-temperature, heating water
Min. Supply-temperature, cooling
8
WKF 85
Heating or Cooling
optional
kW
optional
kW
kW/Hz/COP
kW/Hz/COP
kW/Hz/COP
kW/Hz/COP
kW/ Hz/COP
kW/Hz/COP
kW/Hz/COP
kW/Hz/COP
kW/Hz/COP
kW
kW/Hz/EER
kW/Hz/EER
kW/Hz/EER
°C
°C
°C
°C
WKF-com-
pact 85
Split-Air/Water
Smart-Control
Ser. 300 l
optional / 9,0
Series
optional
1,1 - 9,3
9,17/56/4,78
7,97/56/4,37
4,87/56/3,34
4,31/54/2,77
3,42/54/2,28
6,74/56/3,23
3,94/56/2,13
-
-
1,6 - 7,2
5,59/49/3,04
7,47/49/3,86
6,9/49/4,42
-20 - +45
+15 - +45
50
7

Advertisement

Table of Contents
loading

Table of Contents