Chapter 5. Configuration Menu
START CHAN
Used to select the channel in which the T1 stream will start. The set-
ting must be consistent with carrier if using a public network.
Choices: 01 through 24
# OF CHAN
Used to select the number of DS0s (channels) that are to be used. The
corresponding DTE rate will be this number times 56K or 64K.
Choices: 01 through 24
DATA
Used to control the inverting of the DTE data. This inversion can be
useful when operating with an HDLC protocol. Often used as a
means to ensure ones (1s) density. TSU ACEs on both ends must have
identical option settings.
Choices: NORMAL, INVERT
CTS
Used to control characteristics of CTS.
Choices: NORMAL (see Table 5-1), FORCE ON
DCD
Data Carrier Detect - Indicates to the DTE when a valid signal is being
received at the Network Interface.
Choices: NORMAL (see Table 5-1), FORCE ON
DSR
Data Set Ready - This signal indicates to the DTE when the DCE is
turned
and ready for operations.
ON
Choices: NORMAL (see Table 5-1) or FORCE ON
61200295L1-20
TSU ACE User Manual
5-7