6. Piping installation

Water Charging

Fill water into the outdoor unit by opening shut-off & drain valve.

Charging water to the water-circuit

After installation is completed, the following procedures shall be used to charge water into the outdoor unit.
• Connect water lines to water connections of air-water heat pump.
• Air vent valve shall be open at least 2 turns so that air can be eliminated in the system.
• Open the shut-off & drain valve in the water supply connection.
• Water pressure of supply line shall be over 2.0 bar for good charging work.
• Stop water supply when the pressure gauge of the tank integrated hydro unit indicates around 2.0 bar.
Mono tank
integrated hydro unit
Installer reference guide / Mono tank integrated type
Water outlet
Water inlet
No.
Name
Outdoor outlet
Outdoor inlet
Hot water outlet
Sencondary return (option)
Cold water inlet
Space heating outlet
Space heating inlet
Size
ø28, T1.2, Copper
ø28, T1.2, Copper
ø22, T1.0, Copper
ø22, T1.0, Copper
ø22, T1.0, Copper
ø28, T1.2, Copper
ø28, T1.2, Copper
Conncetions