Mono Ht Quit Electrical Wiring Diagram Outdoor Unit - Samsung EHS AE050RXYDEG/EU Manual

Table of Contents

Advertisement

12. Technical data

Mono HT Quit Electrical wiring diagram outdoor unit

• AE080/120/140BXYDEG/EU
ASSY PCB SUB-EMI
250V T40A
ASSY PCB INVERTER
250V T2A
M(BLDC)
Compressor
ASSY PCB MAIN-OUT
250V T2.5A
HOT GAS
4WAY VALVE
EVI SOL
BASE HEATER
EVI BYPASS
PHE HEATER
HIGH PRESSURE SENSOR
LOW PRESSURE SENSOR
NOTE
• Symbols show as follow :
BLK: black, RED: red, BLU: blue, WHT: white, YEL: yellow, BRN: brown, SKY: skyblue, GRN: green
• Wiring indoor-outdoor communication F1-F2
Protective earth (SCREW)
Installer reference guide / Mono tank integrated type
Printed circuit board(EMI)
FUSE
Printed circuit board(INVERTER)
FUSE
Fan motor outdoor
Compressor
Printed circuit board(MAIN)
FUSE
Solenoid valve Hot Gas Bypass
Solenoid valve 4Way
Solenoid valve Liquid Bypass
Base plate heater
Solenoid valve EVI Bypass
Plate Heat Exchanger Heater
High pressure sensor
Low pressure sensor
HIGH PRESSURE SWITCH 1
HIGH PRESSURE SWITCH 2
WATER OUT-TH
WATER IN-TH
EVI OUT-TH
EVI IN-TH
EVA IN-TH
SUCTION-TH
OLP-TH
DIS-TH
COND-TH
OUT-TH
EEV
EEV-1
EEV-2
High pressure switch 1
High pressure switch 2
PHE Water OUT sensor
PHE Water IN sensor
EVI OUT sensor
EVI IN sensor
PHE Liquid refrigerant sensor
Compressor IN sensor
Over Load Protection sensor
Compressor OUT sensor
Condenser OUT sensor
Ambient sensor
Electronic Expansion Valve (MAIN)
Electronic Expansion Valve (EVI)
Electronic Expansion Valve (Shut Off)
195

Hide quick links:

Advertisement

Table of Contents
loading