Mono Refrigerant Circuit Diagram Outdoor Unit - Samsung EHS AE050RXYDEG/EU Manual

Table of Contents

Advertisement

12. Technical data

Mono Refrigerant circuit diagram outdoor unit

• AE050/080/120/160RXYD*G/EU
V_4W
PT_C
PW_H1
Muffler
T_D
T_CT
COMP
Part
COMP
AC
HX_PHE
HX_M
Heat Exchanger - Main (Outdoor unit)
OFM1
OFM2
V_4W
E_M
Electronic Expansion Valve - Main
PW_H1
Installer reference guide / Mono tank integrated type
OFM1
HP s/w
HX_M
PT_C
AC
Description
Inverter Compressor
Accumulator
Heat Exchanger - PHE
Outdoor Fan Motor 1
Outdoor Fan Motor 2
Solenoid valve - 4Way
Pressure Switch
T_CO
T_A
(E_M)
Muffler
Part
PS_H
PT_C
T_A
T_C
T_D
T_CO
T_II
T_WI
T_WO
T_WI
T_II
Description
Pressure Sensor - High
Service Port - Charging
Thermistor - Ambient
Thermistor - Compressor
Thermistor - Discharge pipe
Thermistor - Cond Out
Thermistor - Heat Exchanger In
Thermistor - Water In
Thermistor - Water Out
201