6. Piping installation
NOTE
• To avoid damage to the surroundings due to water leakage, it is recommended to close the domestic cold
water inlet shut‑off valves during periods of absence.
• It is recommended to install shut‑off valves to domestic cold water in and DHW out connections. These
shut‑off valves are field supplied.
Piping diagram
No.
Note
①
3 way diverting valve
②
Drain Valve
③
T‑Joint
④
Tundish
⑤
Expansion vessel
※ The table above contains the different components of the functional diagrams.
For the reliable performance and durability, all parts as listed below ,including a relief valve, an expansion vessel, a drain
valve and pressure reducing valve , should be installed according to each national or regional standards. They are not
supplied by Samsung.
• Pressure relief valve
• Expansion vessel
• Drain valve
• Tundish
• Expansion relief valve
• Pressure reducing valve
Installer reference guide / Mono tank integrated type
WATER MAIN OUT
Heat pump in
TPRV
Heat pump out
1
Tank Temp
[MONO]
2
No.
⑥
⑦
⑧
Tank Temp
3
Sanitary warm water Tank Diagram(Field Scope)
( * )
3
( * )
4
5
Expansion relief Valve
Pressure reducing valve with integrated check valve and strainer
Temperature sensor for DHW tank
WATER MAIN IN
8
( * )
( * )
6
7
Note
T‑Joint
66