Appendix A
Appendix A.
Mute Timing Sequences
Muting Sequence with Two Muting Devices
(For example, "X"-pattern Entry/Exit System, see Figure B-1)
DIP Switch Configuration*:
Manual Reset . . . . . . . . . . . .SW1 = OFF
Monitored Muting Lamp . . . .SW2 = OFF
Two-Way Muting . . . . . . . . .SW3 = ON
EDM Functional . . . . . . . . . .SW4 = OFF
One-Channel EDM . . . . . . . .SW5 = OFF
ME Functional . . . . . . . . . . .SW6 = OFF
30-Second Backdoor Timer .SW7&8 = OFF
*Both DIP switch banks A and B.
Muting Sequence with Four Muting Devices
(For example, an Entry/Exit System using four photoelectric devices; see Figure B-5)
DIP Switch Configuration*:
Manual Reset . . . . . . . . . . . . .SW1 = OFF
Monitored Muting Lamp . . . . .SW2 = OFF
One-Way Muting . . . . . . . . . .SW3 = OFF
EDM Functional . . . . . . . . . . .SW4 = OFF
One-Channel EDM . . . . . . . . .SW5 = OFF
ME Functional . . . . . . . . . . . .SW6 = OFF
30-Second Backdoor Timer . .SW7&8 = OFF
*Both DIP switch banks A and B.
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Power
MSSI
System Reset
OSSD Outputs
EDM
Closed
Open
Mute Enable
M1
Mute
{
Inputs
M2
Mute Cycle
Power
ON
MSSI
System Reset
OFF
OSSD Outputs
EDM
Closed
Open
Mute Enable
M1
Mute
{
Inputs
M2
M3
Mute
{
Inputs
M4
Mute Cycle
NOTE: A mute cycle begins 100 ms after the second
mute input becomes active, if all other
conditions are met.
ON
Open
Closed
Reset
OFF
ON
Open
Open
Closed
Closed
Closed
Mute
Less than
3 seconds
Normal mute cycle
Mute cycle prevented
OSSD outputs
remain ON
Mute Enable input
Open
Closed
Reset
ON
Open
Closed
Closed
Closed
Closed
Mute
Less than
3 seconds
One-Way Muting:
Normal mute cycle
Mute cycle prevented
OSSD outputs
due to mute devices
remain ON
M3 and M4 closing
before M1 and M2.
Two-Way Muting:
A normal mute cycle
would occur.
MM-TA-12B Muting Module
Instruction Manual
Open
Reset
OFF
Closed
Mute cycle prevented
due to open
due to simultaneity
not being met
Open
Open
Reset
OFF
Mute
Mute cycle drops out
and the FSD outputs open due
to M3 and M4 not closing before
M1 or M2 open, when the
defined area is blocked.
Since one-way muting has been
selected, M3 and M4 can not
initiate a mute cycle.
Open
Reset
OFF
More than
3 seconds
OFF