Banner MM-TA-12B Instruction Manual page 36

Muting module
Table of Contents

Advertisement

System Installation
Brown
Grn/Yel
Blue
1
7
6
Black
5
2
8
White
3
4
Violet
Orange
Org/Blk
WARNING . . .
The generalized wiring configurations shown are provided only to
illustrate the importance of proper installation. The proper wiring
of the MM-TA-12B Muting Module to any particular machine is
solely the responsibility of the installer and end user.
CAUTION . . .
Always disconnect all power from the MM-TA-12B Muting Module
and the guarded machine before making any connections or
replacing any component. Use extreme caution to avoid electrical
shock at all times. Serious bodily injury or death could result.
Figure 3-17. Generic hookup: FSD, two-channel EDM, Mute Enable
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
24V dc
FSD
#1
FSD
#2
Mute
Enable
Single-Channel
Safety Stop Circuit
Dual-Channel
Safety Stop Circuit
Installation of transient (arc) suppressors across
the coils of FSD1 and FSD2 is recommended (see
Warning). Note: Do not exceed OSSD maximum
load capacitance specifications.
Proper Wiring
Shock Hazard
MM-TA-12B Muting Module
0V dc
Transient suppressors are rec-
ommended. They MUST be
installed across the coils of the
machine control elements.
NEVER install suppressors
directly across the outputs of
the Module! It is possible for
suppressors to fail as a short
circuit. If installed directly
across the contacts of the
Safety Module, a short-circuit-
ed suppressor will create an
unsafe condition.
operation, the MM-TA-12B
OSSD output parameters and
machine input parameters must
be considered when interfacing
the MM-TA-12B solid-state
OSSD outputs to machine
inputs. Machine Control circuit-
ry must be designed so that the
maximum load resistance value
is not exceeded and that the
maximum specified OSSD OFF-
state voltage does not result in
an ON condition. Failure to
properly interface the OSSD
outputs to the guarded machine
could result in serious bodily
injury or death.
Instruction Manual
WARNING . . .
Use of Transient
Suppressors
WARNING . . .
OSSD Interfacing
To ensure proper