Banner MM-TA-12B Instruction Manual page 19

Muting module
Table of Contents

Advertisement

MM-TA-12B Muting Module
Instruction Manual
Machine Interface
Pin Color*
Function
1
Brown
+24V dc
2
Orange/Black
EDM#2
3
Orange
EDM#1
4
White
OSSD#2
5
Black
OSSD#1
6
Blue
0V dc
7
Green/Yellow
Earth Ground
8
Violet
Mute Enable
Mute Inputs (M1 – M4)
Pin Color*
Function
1
Brown
+24V dc
NPN INPUT for M2/M4
2
White
(not connected M1/M3)
0V dc
3
Blue
4
Black
PNP INPUT for M1/M3
(not connected M2/M4)
Shield, Earth Ground
5
Shield**
Reset Input
Pin Color*
Function
1
Brown
+24V dc
2
White
(not connected)
3
Blue
(not connected)
4
Black
Reset Input
5
Shield**
Shield, Earth Ground
Override Input (OVER)
Pin Color*
Function
1
Brown
+24V dc
2
White
OVER Input B
3
Blue
0V dc
4
Black
OVER Input A
5
Shield**
Shield, Earth Ground
Maximum cable length (ft) versus total current draw (It) at the Machine Interface connector
0.5A
0.75A
12 AWG
1500
1000
14 AWG
960
640
16 AWG
600
400
18 AWG
375
250
20 AWG
240
160
22 AWG
150
100
NOTE: Cable length includes power (+24V dc) and return (0V dc) wires at 25°C, and is intended to ensure that adequate
power is available to the Module when the supply is operating at +24V dc-15%.
Figure 3-3. Connector pin-outs (face views) for Module connectors
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
1
7
6
5
2
8
3
4
Male, Mini-Style
1
2
5
4
3
Female, Euro-Style
1
2
5
4
3
Female, Euro-Style
1
2
5
4
3
Female, Euro-Style
1.0A
1.25A
1.5A
1.75A
750
594
500
438
480
380
320
280
300
238
200
175
188
148
125
109
120
95
80
75
59
50
Muteable Safety Stop Interface (MSSI)
Pin Color*
Function
1
Gray/Black
MSSI b
2
White
MSSI c
3
Black
MSSI a
4
Blue
0V dc
5
Brown
+24V dc
6
Gray/White
MSSI d
7
Green/Yellow
Earth Ground
Universal Safety Stop Interface (USSI)
Pin Color*
Function
1
Brown
USSI b
2
White
USSI c
3
Blue
USSI d
4
Black
USSI a
5
Shield**
Shield, Earth Ground
Mute Lamp Output (ML) and Auxiliary PNP Output (AUX)
Pin Color*
Function
1
Brown
+24V dc
2
White
Mute Lamp Output
3
Blue
0V dc
4
Black
AUX PNP Output
5
Shield**
Shield, Earth Ground
NOTE: Cable and wiring is low voltage; running these wires along-
side power wires, motor/servo wires, or other high-voltage
wiring can inject noise into the safeguarding system. It is
good wiring practice (and may be required by code) to iso-
late wires from high-voltage wires.
*Color code corresponds to Banner accessory QD cordsets list-
*
ed in Section 2.1.
**Pin 5 is for an optional connection for shield ground in electri-
cally noisy environments
2.0A
2.25A
2.5A
375
344
313
240
220
200
150
138
125
94
88
78
70
60
55
50
44
38
n.a.
n.a.
System Installation
6
1
7
5
2
4
3
Female, Mini-Style
1
2
5
4
3
Female, Euro-Style
1
2
5
4
3
Female, Euro-Style
2.75A
3.0A
3.25A
281
250
219
180
160
140
113
100
88
70
63
55
45
40
35
n.a.
n.a.