Banner MM-TA-12B Instruction Manual page 22

Muting module
Table of Contents

Advertisement

System Installation
3.5.2.3 Muting Device Hookup
The Module provides supply voltage, if required, and input
connections for the muting devices. One or two pairs of
muting devices (typically sensors or switches) must be
used; these pairs are designated M1-M2 and M3-M4. The
M1 and M3 inputs are PNP (sourcing). The M2 and M4
inputs are NPN (sinking). Also available are terminals to
supply power (+24V dc) to the muting devices, which are
labeled "+24V dc" and "0V dc."
The current draw of all devices must not exceed 500 mA.
+
+
Figure 3-5. Two photoelectrics as M1 and M2 (or M3 and M4)
using relay outputs
PNP
Carrier
Basket
Figure 3-7. Four sensors as M1, M2, M3 and M4, using semiconductor outputs and power connections interfaced with Y-cables
(or splitters)
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
M1 (and M3)
+
1
2
5
4
3
M2 (and M4)
+
1
2
5
4
3
Figure 3-6. Four limit switches as M1, M2, M3 and M4
PNP
E
R
Light
Screen
NPN
NPN
MM-TA-12B Muting Module
M1
M3
R
Carrier
Basket
E
M2
M4
Light
Screen
1
5
4
Y-Cable
1
5
4
Y-Cable
1
5
4
Y-Cable
1
5
4
Y-Cable
Instruction Manual
1
2
M1
5
4
3
1
2
M3
5
4
3
1
2
M4
5
4
3
1
2
M2
5
4
3
2
M1
3
2
M2
3
2
M3
3
2
M4
3

Advertisement

Table of Contents
loading

Table of Contents