en | Appendices
Table 11.10: Host / Extension interface
Table 11.11: External tamper contact
11.2

Status display

11.2.1
Bootloader V00.49
Push
0
1
2
3
4
5
6
7
8
9
10
11
12
2022-11 | V05 |
1
Power supply (10V - 30V)
2
Power supply GND
3
Shield
4
Data RxTx+
5
Data RxTx-
6
PAG
1
Tamper Contact, in
2
Tamper Contact, out
Display (Example)
V00.49 dd.mm.yy
S/N1: 0910024419
S/N2: 22850034
11.18 12:24:18 S
MAC 001B860012AB
N AMC-1234-5678
I 192.168.10.18
G 192.168.10.255
M 255.255.255.0
H 192.168.10.10
DHCP 1
D 192.168.10.1
Host: + "C"
Руководство по установке
Description
Bootloader version by factory
dd.mm.yy release date of the firmware
Serial number 18 digits - Part1 10 digits
Part 2 - 8 digits
Current date and time (MM.DD hh:mm:ss)
(S) = daylight saving
Network device address (MAC)
Network name of the controller (max. 14 char.)
See Configuring Ethernet interface, page 32 .
IP-address of the controller
IP-address of the gateway
Subnetmask
IP-address of the host computer
DHCP-status: 1 = on; 0 = off
IP-address of the DNS server
Host activity:
+ = online
- = offline
"C" = Counter (0 to 9) of the received data
packages from the host interface.
RS 485 Bus connection:
A = Address 1 ... H = Address 8
Access Modular Controller 2