Access Modular Controller 2
Notice!
i
If using an Ethernet connection, set switch 1 and 5 to ON (= delivery status).
Figure 4.13: Location of the selector for host settings
Address
none
1
2
3
4
5
6
7
8
Table 4.1: Setting the address via the DIP switch
Mode
ON
OFF
Table 4.2: Protocol and connection settings
Host settings
Instructions for DIP switch 5
Set SDEB (= DIP switch 5 to ON) in the following cases:
Set BPA (= DIP switch 5 to OFF) in the case of an:
4
Bosch Security Systems B.V.
DIP switches
1
2
OFF
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
DIP switches
5
6
SDEB
PI
BPA
RS-485
Ethernet host connection
RS-485 host connection, provided only one AMC2 is connected on the bus.
RS-485 host connection with more than one and maximum eight AMC2s per bus.
Руководство по установке
3
4
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
ON
Installing | en
25
2022-11 | V05 |