(2) Warning types
 General warning
Warning
No.
Warning
(Hex.)
Overload
A0
warning
Over-regeneration
A1
warning
A3
Fan warning
Oscillation
A6
detection warning
Lifetime
A7
detection warning
Feedback scale
A8
error warning
Feedback scale
A9
communication
warning
 Extended warning
Warning
No.
Warning
(Hex.)
Main power off
C3
warning
R1.00
The specification for warning detection
varies depending on the values of Pr6.73
(Over-load warning detection level) and Pr6.74 (Over-load warning
release level), and it becomes as shown in the table below.
Pr6.73
Pr6.74
Pr6.73
Pr6.74
Magnitude
relation
Pr6.73>=
Pr6.74
Other
than 0
Other
Pr6.73<
than 0
Pr6.74
0
Other
-
than 0
0
0
Regenerative load factor is 85% or more the protection level.
Fan has stopped for 1 sec.
If Pr6.37 (oscillation detection level) is non-zero, it is detected that the
torque oscillation (oscillation state) than that specified in Pr6.37.
Life expectancy of capacitor or fan becomes short.
The feedback scale detects the warning.
The number of successive feedback scale communication errors exceeds
the specified value.
When setting of Pr7.14 (Main power off
warning detection time) is 10-1999,
instantaneous power interruption occurs
between L1 and L3 and lasts for a time longer
than the setting of Pr7.14.
Content
Warning
Warning
detection
release
specification
specification
Load factor
Load factor
is more
less than
specifications
Pr6.73
Pr6.74
Load factor
Load factor
Please do not
is 85% or
is less than
more of the
85% of the
protection
protection
level
level
Conventional
specification
Content
Motor Business Unit, Panasonic Corporation
No. SX-DSV02829 -
Output
Waning mask
setting
Pr
Pr 6.38
4.40/
Corresponding
Pr 4.41
*1)
Remarks
Extended
1
set
2
4
7
8
9
10
Output
Waning mask
setting
Pr 4.40/
Pr 6.38
Pr 4.41
Corresponding
*1)
bit
*2)
14
bit 12
160-
bit
*2)
bit 7
bit 5
bit 6
bit 13
bit 2
bit 8
bit 14