6-2. Measurement of propulsion motor (R)

Oil temperature during measurement : 50
① Remove plug from parking brake pilot port (1). Attach
pressure gauge with adapter ⓑ .
Adapter ⓑ
Pressure gauge : 0 to 5 MPa (0 to 725 psi)
② Confirm that F-R lever is "N".
③ Apply parking brake by pressing parking brake switch
button.
④ Start the engine and set throttle lever to "FULL".
⑤ Release parking brake by pressing parking brake switch
button.
⑥ Read brake release pressure indicated by pressure
gauge.
Brake release pressure
°C (122
± 5
: G1/4
: 1.3 to 1.6 MPa (189 to 232 psi)
INSPECTION AND ADJUSTMENT
°F)
± 9
b
b
1
1
Propulsion motor (R)
Propulsion motor (R)
R2H-2-09006
R2H-2-09006
PG001002
PG001002
9-009