Continuous Water Spray Works, But Intermittent Water Spray - Sakai R2-4 Shop Manual

Table of Contents

Advertisement

2-5-2. Continuous water spray works, but intermittent water spray does not operate
Water spray mode select switch must be "INT".
Reference Fig.: 2-5-1
Check point
1. Water Spray Timer
2. water Spray Mode
Select Switch
3. Harness Connecting
Between Terminals
Check/Cause
(1) when starter switch is ON, measure voltage between
water spray timer terminal 1 inlet wire LR and terminal 3
inlet wire LB and chassis ground.
Standard voltage : 12 V or more
(2) when starter switch is ON, measure voltage between
water spray timer terminal 4 outlet wire LY and chassis
ground.
Standard voltage : 12 V or more with constant intervals
If above item (1) is OK and item (2) is NG, water spray
timer is faulty.
(1) when starter switch is ON, measure voltage between
water spray mode select switch terminal 4 inlet wire LB
and chassis ground.
Standard voltage : 12 V or more
(2) when starter switch is ON, measure voltage between
water spray mode select switch terminal 5 outlet wire
LR and chassis ground.
Standard voltage : 12 V or more
If above item (1) is OK and item (2) is NG, water spray
mode select switch is faulty.
Measure resistance of harness connecting between
terminals.
Standard resistance : 10 Ω or less
If resistance is abnormal, harness is faulty.
TROUBLESHOOTING
Action
Replace water spray
timer.
Replace water spray
mode select switch.
Repair or replace
harness.