Terminal Block B
Sensor B
Sensor A
Color
B1
B9
B2
B10
B3
B11
White
B4
B12
Not Used
B5
B13
Not Used
B6
B14
Black
B7
B15
Not Used
B8
B16
Co-ax Inner
Table 6.3 ABB AP100, AP200 and AP300 Series pH Sensor Connections
Terminal Block B
Sensor B
Sensor A
B1
B9
B2
B10
Not Used
B3
B11
B4
B12
Not Used
B5
B13
Not Used
B6
B14
B7
B15
Not Used
B8
B16
Table 6.4 ABB TB5 and TBX5 Series pH Sensor Connections
Note.
1. Where pH systems are used with a Solution Earth (ground rod) and those including diagnostics, ensure that
the relevant sensor(s) is set to
2. If the sensor is fitted with a 2-wire Pt100, Pt1000 or Balco 3K temperature compensator, link terminals B9 and B10 (and B1
and B2 if dual input analyzer).
The redox (ORP) version of the AP100, AP200 and AP300 series does not incorporate a temperature sensor. The
Temperature sensor must be disabled in the Configuration page - see section 5.3, page 30.
IM/AX4PH
Issue 9
AP100 Series Sensors
Function
Red
Temperature
Compensator
Common
Red
Temperature
Compensator 3rd Lead
Temperature
Compensator
Not Used
Not Used
Reference
Not Used
Glass/Metal Electrode
TB5 Series Sensors
Color
Function
White
Temperature Compensator (if fitted)
-see also Note 2 below
Link to White
Red
Temperature Compensator (if fitted)
Not Used
Not Used
Black
Reference Electrode
Not Used
Blue
Glass/Metal Electrode
- see section 5.3, page 30.
Yes
AP200 Series Sensors
(see Note below)
Color
Function
Grey
Temperature
Compensator
Common
White
Temperature
Compensator 3rd Lead
Green
Temperature
Compensator
Blue
Reference
Not Used
Not Used
Green/
Solution Earth
Yellow
(Ground Rod)
Red
Screen/Shield
Transparent
Glass/Metal Electrode
TBX5 Series Sensors (see Note 1 below)
Color
White
Not Used
Red
Black
Not Used
Green
Yellow
Blue
6 INSTALLATION
AP300 Series Sensors
Color
Function
White
Temperature
Compensator
Common
Grey
Temperature
Compensator 3rd Lead
Red
Temperature
Compensator
Not Used
Not Used
Not Used
Not Used
Black
Reference
Not Used
Not Used
Blue
Glass/Metal Electrode
Function
Temperature Compensator (if fitted) -
see also Note 2 below
Link to White
Temperature Compensator (if fitted)
Reference Electrode
Not Used
Solution Earth (Ground Rod)
Screen/Shield
Glass/Metal Electrode
Diff. Input
for
55