Attachment installation
As an example; if the maximum aggregate size is 16 mm, a Ø20
mm vertical bar and a Ø12 mm horizontal bar are used in a column.
The minimum size to closest bar must then be 21 mm, hence the
determined value is d
or 20 mm are both 20 mm. Thus, the minimum distance can never
be less than 21 mm. Please see Figure 18 for an example.
Figure 18. Accepted position for the Cast-in Sleeve in two
1. Column width
2. Cmin
3. Cast-in Sleeve
4. Boundary line for accepted position of the Cast-in Sleeve
3. After the leveling is done, the plastic plug can be returned to the
top of the sleeve to avoid ingress of water and debris.
The SkyReach Anchor has been tested and approved, according to
EN 795:2012 Type B, in a Cast-in Sleeve cast into a column with
the cross section 250 x 250 mm. In case of columns with smaller
dimension, please contact Combisafe for installation details.
NOTE
Always wait at least 24 hours after pouring concrete before the
SkyReach Anchor is installed and used. Otherwise the concrete
may not be strong enough to withstand the loads that will occur
from a fall.
= 16+5=21 mm. The two other options Ø
g
1
different set-ups.
SkyReach Anchor
4
3
;
bar
21