Figure 17. Levelling the Cast-in Sleeve body.
NOTE
During concrete hardening, uplift of the Cast-in Sleeve may
occur. To prevent this, the tube should be encumbered or
alternatively may be wired to rebars to keep the protruding
tolerance.
In Figure 18, the cross-section area of a column, and the acceptable
position of the Cast-in Sleeve, is shown. The acceptable position
of the sleeve is varying depending according to the following
formula:
C
=maximum value of (d
min
C
: minimum distance between the outer surface of the Cast-in
min
Sleeve and closest reinforcement bar
d
: maximum size of aggregate used in concrete
g
Ø
: maximum diameter of any of the reinforcement bars used in
bar
the column
20
+5mm);(Ø
);(20 mm), where:
g
bar