Star Coupler Feature

iSTAR eX Capacities

Battery – connector to 12 VDC, 17.2 Ah minimum capacity standby battery
PMB to ESD – battery charging connector
ESD power – UL Recognized ESD, Model SPS-6.5, supplies power to the PMB
Fuse – 10 A, 250 VAC fuse
The GCM board and the software support two ports for connecting readers and other
peripherals. Each port can control up to four readers. The PMB provides a star coupler feature
to expand the two RS485 ports into four ports with separate drivers (referred to as RM ports)
as shown in Table 1-7 on
The PMB star coupler uses a DIP Switch (S1) to route the RM ports to the RS485 ports on the
GCM.
GCM
16 general purpose inputs –- can be supervised with traditional Software House Double
NO/NC 1K, or various other 1K, 5K, 10K, Unsupervised methods.
Four Wiegand direct connect read heads
Four relay outputs
Four open collector outputs
PMB
Serial – eight I/8s, eight R/8s, four or eight RM Readers on up to four RM busses.

Input/Output Capacities

T
he maximum configuration per iSTAR eX controller is eight (8) RM (RS485) readers, eight I/
8 Modules, and eight R/8 Modules, for a total of:
96 inputs - does not include the special inputs for Tamper, AC Fail, and Battery Low.
88 outputs - does include the 4 Open collector (OC) outputs..