Mounting the Enclosure

Mounting the Enclosure
Observe standard precautions about static electricity when handling hardware components.
1–20
This section describes how to mount the iSTAR eX components in a standard metal enclosure,
as shown in Figure 1-7.

Static Electricity

Before handling internal components, discharge static electricity by touching grounded
Wear a grounding wrist strap and stand on a grounded static protection mat.
Limit movement during installation to reduce static buildup.
To mount the iSTAR eX controller
1. Verify that the upper mounting screws (or equivalent) are in place on the mounting site.
2. Carefully unpack the components. Observe static electricity precautions.
3. Open the enclosure door. Carefully lift the door off the hinges and place it on a padded
surface.
4. Align the mounting keyhole slots at the upper back of the enclosure with the two upper
mounting screws and lower the enclosure into position.
5. Install the two bottom mounting screws.
Mounting
keyhole slots
Bottom
mounting holes
6. Remove the appropriate knockouts for wiring the inputs and outputs.
7. Attach conduit couplings to the knockout openings as needed to comply with code.
14-1/4"
Figure 1-7: Mounting the iSTAR eX controller
22-1/4"

Advertisement