Numbering Registers And I/Os; Fig. 19 Example: Register Numbers; Fig. 20 Example: I/O Numbers - Jetter JetControl 365MC User Manual

Table of Contents

Advertisement

Jetter AG

8.4.1 Numbering registers and I/Os

Module registers -
Definition
Access options
INFO
100XXZZZZ
Fig. 19: Example: Regis-
ter numbers
10000XXZZ
Fig. 20: Example:
I/O numbers
User Manual – JetControl 365MC
Module registers are the data interface of the expansion module. Module regis-
ters let you read process, configuration and diagnostics data from the expansion
module, or write such data to it.
The module register number within a module is unique.
This unique register number lets you access a specific module register within
the system.
There are several ways to access registers directly:
From an application program
From the JetSym setup pane
From a visualization application
The register number within the system is unique.
Further information
For more information on this subject refer to the application-oriented manual
JX3 System available for download from our homepage.
Expansion modules connected with a controller
Our products offer a host of functions which can be accessed by the user via reg-
isters. Every register has got an unambiguous number, the register number. Each
digital input or output has got an unambiguous I/O number.
Register numbering system
Register numbers consist of a prefix, the module position in the system and the
module register number. If the expansion modules are connected with the con-
troller via JX3 system bus, the prefix is 100. In this case, the module register
number is always a four-digit number.
Digits
Description
100
Prefix
XX
Position of the module in the system
ZZZZ
Module register number
I/O numbering system
The inputs or outputs of the module are directly accessed via I/O numbers. These
I/O numbers consist of a five-digit prefix, the module position in the system and
the I/O number of the module. The I/O numbers always start with the constant
prefix 10000.
Digits
Description
10000
Prefix
XX
Position of the module in the system
ZZ
Module-specific I/O number
Programming | 8
Value range
02 ... 17
0000 ... 9999
Value range
02 ... 17
01 ... 16
90 / 148

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jetcontrol 365Jc-365mc

Table of Contents