REP 4.28 Halogen Lamp
WARNING
Fuser components are hot. Wait until components
cool before you begin work.
Removal
1.
Remove the following:
a.
Fuser Assembly (REP 4.24).
2.
Remove two screws from the fuser assembly.
REP 4.28 Halogen Lamp
Be careful not to bend the IPR Ground Plate.
3.
Unsnap and remove the heat roller from the Fuser Assy.
IPR Ground
Plate