REP 4.23 HVPS PBA
Removal
1.
Remove the following:
a.
Side Covers (REP 4.15).
2.
Remove five screws from the HVPS PBA.
WorkCentre 385
3.
Unplug four connectors from the HVPS PBA, then remove the PBA.
Note: When you reassemble the HVPS PBA, make sure that the high
voltage electrodes, contacts, springs and pins are inserted correctly.
Replacement
1.
Reinstall the components in the reverse order.