DX Power
Possible Cause and Action
Module
Status LED
Flash Code
2
Temperature Fault
Cause: Either there is a temperature sensor fault or the Power
Action < Turn system off, wait a few minutes for the system to
3
Left (M1) Motor Fault
Cause: The connection from the PM left (M1) connector to its
Action < Disconnect the left motor plug and check continuity
Action < Ensure there is no continuity between motor and park
4
Right (M2) Motor Fault
Cause: The connection from the PM right (M2) connector to its
Action < Disconnect the right motor plug and check continuity
Action < Ensure there is no continuity between motor and park
5
Left (M1) Park Brake Fault
Cause: The M1 plug connection to its associated Park Brake is
Action < Disconnect the M1 plug and check continuity
Action < Ensure there is no continuity between motor and park
Cause: The Park Brakes are connected to M2 not M1. When
Module's internal temperature is above or below the
programmed operating temperatures.
stabilise, and turn system back on.
< If fault re-occurs, consult your Dynamic Service
Centre.
associated motor, or the motor itself, is defective. The
connection is either open or short circuit.
between the motor pins on M1.
brake terminals.
associated motor, or the motor itself, is defective. The
connection is either open or short circuit.
between the motor pins on M2.
brake terminals.
either open or short circuit.
between the two Positronic Park Brake pins.
brake terminals.
programmed as 'sngl', the Park Brakes must be
connected to PB+ on M1.