%DWWHULHV DQG &KDUJLQJ

%DWWHULHV DQG &KDUJLQJ
%DWWHU\ 7\SH
The DX System is designed to perform optimally with either Lead-Acid or Gel
Cell 24 V deep cycle batteries, rated at 20 - 120 Amp hours. The maximum
average discharge rate must not exceed half the rated capacity, in Amp hours.
High continuous discharge rates dramatically reduces the available battery
capacity. For example, at a discharge rate equal to the rated capacity, the available
capacity is 50 - 60 %. At a discharge rate of half the rated capacity, the available
capacity is 70 - 80 %.
%DWWHU\ &KDUJLQJ
The satisfactory performance of the PM is critically dependent on the type and
condition of the batteries. The battery charger used must be correctly selected and
adjusted according to the battery manufacturer's instructions. Failure to do so may
damage or destroy the batteries, give poor range, or be potentially dangerous.
Batteries should not be abused (for example by deep discharging or overcharging)
and must be operated and maintained according to the manufacturer's instructions.