6DYLQJ &KDQJHV
Changes are saved when the HHP is returned to the main menu screen. If the DX
Remote is turned off before the HHP is returned to the main menu, all changes are
lost.
Changes can be test driven before being permanently saved as the DX System can
be driven with the HHP plugged in. Even if the HHP is disconnected the changes
will remain current unless the DX System is turned off. Once turned off, the
settings will return to the original values.
6HWWLQJ 9HHU &RPSHQVDWLRQ
Ensure that the wheelchair tyres have balanced pressures before attempting to
adjust Veer Compensation. This parameter should be adjusted when a motor is
replaced. This parameter has no effect on the PM-S.
1. Enable the Technician Mode
2. Press 'NEXT' in the main menu until the screen reads :
Press 'YES'.
Pressing 'EXIT' at any point during the following procedure will return you to
Ô
screen
.
3. Calibrate the Veer Compensation (Veer (right +)) Parameter.
Press 'LEFT' and 'RIGHT' to adjust the value.
Ô
* * MAIN MENU * *
View or edit Power
Module ? (Tech Only)
NEXT
VIEW/EDIT POWER MOD
Veer compensation
EXIT
NEXT
YES
Right 0%
LEFT
RIGHT
53
3URJUDPPLQJ
Need help?